Daily Maintenance; Empty Purge Container; Remove Debris Buildup; Weekly Maintenance - Stratasys Prodigy Plus User Manual

Table of Contents

Advertisement

44 Maintenance

Daily Maintenance

Empty Purge Container

The black, plastic purge container is attached to the rear wall of the
modeling chamber, on the right side (see
1. Remove the purge container by grasping it and pushing it
upward to release it from the three mounts.
2. Pull the container towards you and out of the chamber to
empty it.

Remove Debris Buildup

Remove any material buildup on the Z-platform and around the
lead screw. Failure to do so could cause the base to become
unleveled or, if the buildup is large enough, it could cause the Z-
stage to jam at its upper limit.

Weekly Maintenance

Vacuum Build Chamber

Vacuum the build chamber to remove all foreign particles and
purged material.
Prodigy Plus User Guide
When reinstalling the container, ensure that
it locks in all three mounts and hangs flush
with the chamber wall to avoid damage.
Figure 1
on
WARNING
page
11).