Channel Selecting - R&S NGE100B Series User Manual

Hide thumbs Also See for NGE100B Series:
Table of Contents

Advertisement

®
R&S
NGE100B
Return values:
<arg0>
Usage:
HCOPy:SIZE:X?
This command returns the horizontal expansion of the screenshots.
Return values:
<arg0>
Usage:
HCOPy:SIZE:Y?
This command returns the vertical expansion of the screenshots.
Return values:
<arg0>
Usage:

6.5.5 Channel Selecting

INSTrument:NSELect <arg0>
This command defines or queries the numeric selection of a channel. Each channel of
the power supply is considered as separate "instrument", which is required by the SCPI
standard.
Parameters:
<arg0>
Example:
INSTrument[:SELect] <arg0>
This command defines or queries the channel selection. Each channel of the power
supply is considered as separate "instrument", which is required by the SCPI standard.
Parameters:
<arg0>
User Manual 5601.1343.02 ─ 04
Query only
Query only
Query only
{1 | 2 | 3}
INSTrument:NSELect 1
Selects the output channel as Ch 1.
Note: Channel 3 is only valid for NGE103B.
INSTrument:NSELect? -> 1
Return the numeric channel selection.
OUTPut1 | OUTPut2 | OUTPut3 | OUTP1 | OUTP2 | OUTP3 |
OUT1 | OUT2 | OUT3
OUTPut1 | OUTP1
Ch 1
Remote Control
Remote Control - Commands
80

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nge103bNge102b

Table of Contents