TRIGger:OUT:CRITevent:DIO<IO> <arg0>
This command sets or queries the critical event of the trigger output of the specified
Digital I/O line.
Suffix:
<IO>
Parameters:
<arg0>
TRIGger:OUT:CURRlevel:DIO<IO> <Current>
This command sets or queries the threshold current level of the the trigger output of
the specified Digital I/O line.
Triggers when output current level exceeds or equals to the set level.
Suffix:
<IO>
Parameters:
<Current>
TRIGger:OUT:SOURce:DIO<IO> <arg0>
This command sets or queries the control source of the trigger output of the specified
Digital I/O line.
Suffix:
<IO>
Parameters:
<arg0>
TRIGger:OUT:VOLTlevel:DIO<IO> <Voltage>
This command sets or queries the threshold voltage level of the the trigger output of
the specified Digital I/O line.
Triggers when output voltage level exceeds or equals to the set level.
User Manual 5601.1343.02 ─ 04
.
1..4
OVP | OPP | OTP
OVP
Trigger output is linked to the OVP event
OPP
Trigger output is linked to the OPP event
OTP
Trigger output is linked to the OTP event
*RST:
OVP
.
1..4
*RST:
3.000
Default unit: A
.
1..4
CH1 | CH2 | CH3
*RST:
CH1