Syntax Element
#
" "

6.3.2 Parameters

For most commands, a parameter needs to be supplemented. The parameter has to
be separated from the header by a "white space".
The type of parameter required for each command and the allowed range of values are
specified in the command description.
Numeric
Special Numeric
Boolean
Text..........................................................................................................................72
Strings..................................................................................................................... 72
Block
6.3.2.1

Numeric Values

Numeric values can be entered in any form, i.e. with sign, decimal point and exponent.
Values exceeding the resolution of the instrument are rounded up or down. The man-
tissa may comprise up to 255 characters, the exponent must lie inside the value range
-32000 to 32000. The exponent is introduced by an "E" or "e". Entry of the exponent
alone is not permissible. In the case of physical quantities, the unit can be entered.
Permissible unit prefixes are G (giga), MA (mega), MOHM and MHZ are also possible),
K (kilo), M (milli), U (micro) and N (nano). If the unit is missing, the basic unit is used.
6.3.2.2

Special Numeric Values

The texts MINimum, MAXimum, DEFault, UP and DOWN are interpreted as special
numeric values. In case of a query, the numeric value is returned.
MIN/MAX
MINimum and MAXimum denote the minimum and maximum value.
DEF
DEFault denotes a preset value which has been stored in the EPROM. This value
conforms to the default setting, as it is called by the *RST command
UP/DOWN
UP, DOWN increases or reduces the numerical value by one step. The step width
can be specified via an allocated step command for each parameter which can be
set via UP, DOWN.
User Manual 5601.1343.02 ─ 04
Values....................................................................................................... 71
Values.......................................................................................... 71
Parameters............................................................................................... 72
Data...............................................................................................................73
SCPI Command Structure and Syntax
Description
The hash symbol # introduces binary, octal, hexa-
decimal and block data.
Binary: #B10110
Octal: #O7612
Hex: #HF3A7
A "white space" (ASCII-Code 0 to 9, 11 to 32 deci-
mal, e.g. blank) separates header and parameter.
Remote Control
71