FUSE:LINK <arg0>
This command defines or queries the channel fuses (fuse linking) for the previous
selected channel.
Parameters:
<arg0>
Example:
FUSE:TRIPped?
This command queries the fuse tripped of the previous selected channel.
Return values:
<arg0>
Example:
Usage:
FUSE:UNLink <arg0>
This command unlinks the channel fuses (fuse linking) for the previous selected chan-
nel.
Parameters:
<arg0>
User Manual 5601.1343.02 ─ 04
{1 | 2 | 3}
1
channel Ch 1
2
channel Ch 2
3
channel Ch 3
INST OUT1
FUSE:LINK 2
Fuse Ch 1 is linked with Ch 2
FUSE:LINK? 2 -> 1
If the fuse of Ch 1 is linked with Ch 2, a "1" is returned.
FUSE:LINK? 3 -> 0
If the fuse of Ch 1 is not linked with Ch 3, a "0" is returned.
ON
Fuse is tripped.
OFF
Fuse is not tripped.
INST OUT1
FUSE:TRIP? -> 0
Fuse of Ch 1 has not tripped.
Query only
{1 | 2 | 3}
1
channel Ch 1
2
channel Ch 2
Remote Control