To reduce the possibility of dust entering the unit and to allow easy
inspection of the unit's front panel lights, make sure that the MAXserver is
located at an optimum distance (preferably not less than 18 inches/45
centimeters) from the floor.
Environment -- Do not choose a location where the unit will be exposed to
direct sunlight or subjected to vibration. Also, the unit must be installed in
an environment with 20% to 80% humidity, noncondensing, 0° - 40° C (32°-
113° F).

Rack Mount Installation (optional)

Rack mount installation is easier when performed by two persons -- one
person holding the unit while another secures the mounting bolts with a
Phillips-head screwdriver. (Threaded clips and bolts are supplied with the
unit).
Complete these steps:
1. Locate a mounting position on the rack that allows at least one inch of
space above and below the unit.
2. Secure the unit to the mounting rack using the supplied bolts, as shown
in Figure 3. If the rack is not threaded, use the threaded clips supplied
with the server.
22
Getting Started with MAXserver Access Servers
+
Do not remove the MAXserver unit's "feet."
Do not place an object on the side(s) of the unit
that might block airflow through the unit.