and plug it back in.
13. When you apply power, the MAXserver performs a self test of its
circuitry and then proceeds to load its software. When the unit has
finished loading its software, the RUN light flashes slowly and the LAN
light flashes as Ethernet packets are received.
If, after several minutes, the front panel lights do not behave as indicated,
refer to the Troubleshooting section.
No other actions are required. The MAXserver automatically detects, tests,
and records the presence of the additional memory. However, if you want to
verify that the MAXserver has detected the additional memory, proceed to
the next section.

Verifying Memory Installation Using Commands

You can verify that the MAXserver has detected the additional memory. To
do so, follow these steps:
1. Connect a terminal to any MAXserver serial port.
2. Press <RETURN> several times to "autobaud" the serial port to the
terminal's speed.
3. Enter a username when prompted.
4. Use the following command to generate a display that indicates the
amount of memory the MAXserver detects. (Look for the "Installed
Memory" field in the upper left portion of the display.)
At the Xyplex prompt, type:
SHOW SERVER ALTERNATE STATUS

Verifying Memory Installation Using the Configuration Menu

You also can use the MAXserver Access server Configuration menu to verify
0038
Getting Started with MAXserver Access Servers
149