Getting Started with MAXserver Access Servers
XYPLEX>>INITIALIZE DELAY 0

Power Up and Re-initialization Problems

The following list describes the problems you might encounter when you
power up or re-initialize a MAXserver. The list includes descriptions of
correct operations and possible solutions.
CARD light does not go ON
Problem: You are trying to load from a Memory card and the CARD light
does not go ON.
Correct Operation: The CARD light should illuminate for approximately
15 seconds when the MAXserver loads software from a flash card.
Possible solutions: If the CARD light does not go ON, make sure that the
card is inserted properly. Also, make sure that the MAXserver is configured
to load from the Memory card. Use the Configuration menu in Figure 27 to
verify. By default, a MAXserver is configured to load from the flash card,
however, someone might have changed this setting.
CARD light goes ON then OFF quickly
Problem: If the CARD light goes ON and then OFF quickly, make sure that
the flash card has been initialized.
Solution: You can initialize a flash card while it is inserted in the unit by
issuing the FORMAT CARD command. Alternatively, if you have a PC with
a flash card drive, you can check whether the SYSTEM directory is present
on the card. The directory should contain the software image. The filename
must be xpcsrv20.sys. Also, the loader file mcffs1.sys must reside in the
same directory as xpcsrv20.sys, and must appear before xpcsrv20.sys.