A-2) Remove the 3 screws [1] and the e-ring [2], and remove the separation drive mount 2 [3] from the separation drive mount 1
[4].
Then, remove the separation drive plate/gear/roller [5] and the separation drive shaft/bearing/19T gear [6] from the separation
drive mount 1 [4].
A-3) Replace the bearing [1] attached to the removed separation drive mount 2 with the new separation drive mount 2.
[Reference] Attach the bearing so that its flange comes to outer side.
A-4) Using the new type separation drive mount 2 and the separation drive mount 1, assemble the parts in the reverse order of
the step A-2). When attaching the e-ring, use the new one that is prepared.
A-5) Attach the separation drive mount 2 and the separation drive mount 1 to the fixing assembly. When doing so, bring the
separation drive mount 2 and the separation drive mount 1 to the lowest position and temporarily secure them with the 2 screws.
A-6) Close the upper fixing unit, insert the fixing positioning pin [1] and secure with the yellow screw [2].