Technical Information
H1P 115/130 Axial Piston Single Pumps
Control Options
©
Danfoss | May 2018
Calibration of the sensor output within the software is mandatory. Vehicle neutral thresholds in the
software (±0.5°) are vehicle dependent and must consider different conditions, example: system
temperature, system pressure and/or shaft speed.
For safety function: If the sensor fails (invalid signal <10% or >90% of supply voltage), it must be sure
that the ECU will go into a diagnostic mode and shift into limited mode in order for the driver to take the
full control or the mechanical breaks should be activated.
Strong magnetic fields in the proximity of the sensor can influence the sensor signal and must be
avoided.
Swash Plate Angle Sensor Connector
DEUTSCH 4-pin connector
4
1
3
2
Connector order numbers
Description
Mating connector DTM06-4S-E004
Wedge lock WM-4S
Socket contact 0462-201-2031
Interface with ECU
Interface with ECU diagram
Supply
ECU
Signal
GND
Legend:
1. Ground (GND)
2. Not connected
3. Output signal 1 (SIG 1)
4. Supply (V+)
Quantity
1
1
3
100 nF
VCC
OUT
GND
100 nF
20 kΩ
Order number
11105824
not available
BC00000198en-US0901 | 37