Controls; Electric Displacement Control (Edc), Option A2 (12 V) / A3 (24 V); Electric Displacement Control (Edc) With Mor, Options A4 (12 V) / A5 (24 V) - Danfoss H1 Series Technical Information

Axial piston single pumps
Hide thumbs Also See for H1 Series:
Table of Contents

Advertisement

Technical Information
H1P 115/130 Axial Piston Single Pumps

Controls

Electric Displacement Control (EDC), option A2 (12 V) / A3 (24 V)

Electric Displacement Control (EDC) with MOR, options A4 (12 V) / A5 (24 V)

©
Danfoss | May 2018
Please contact Danfoss representative for specific installation drawings.
Connector :
Deutsch DT04-2P
to be paint free
79.4 ± 1.0
[3.13 ± 0.039]
Connector :
Deutsch DT04-2P
to be paint free
2x 141.5 ± 1.0
[5.571 ± 0.039]
Shaft L
c
Connector :
Deutsch DT04-2P
to be paint free
79.4 ± 1.0
[3.13 ± 0.039]
Connector :
Deutsch DT04-2P
to be paint free
2x 141.5 ± 1.0
[5.571 ± 0.039]
Shaft L
c
Case gauge port "M14"
Port ISO 11926-1 –
/
-20
7
16
∅21 max clearance dia for fitting
Shaft L
c
Mounting flange
Case gauge port "M14"
Port ISO 11926-1 –
/
-20
7
16
∅21 max clearance dia for fitting
Shaft L
c
Mounting flange
BC00000198en-US0901 | 59
P003 397E
P003 398E