Technical Information
H1P 115/130 Axial Piston Single Pumps
Installation drawings
46.4 ± 1.0
[1.827 ± 0.039]
Case pressure port
Port ISO 11926-1 – 1
/
-12
1
16
∅41.0 max. clearance dia for fitting
X
Approximate center
of gravity
Case drain port "L2"
Port ISO 11926-1 – 1
∅63.0 max. clearance dia for fitting
Case gauge port "M14"
Port ISO 11926-1 –
/
-20
7
16
∅21.0 max. clearance dia for fitting
E-E
©
Danfoss | May 2018
167.4 ± 1.0
[6.591 ± 0.039]
Connector :
141.5 ± 1.0
Deutsch DT04-2P
[5.571 ± 0.039]
to be paint free
Y
Servo gauge port "M5"
Port ISO 11926-1 –
∅24.5 max. clearance dia for fitting
G
158.4
[6.24]
G
Charge gauge port "M3"
/
-12
5
16
Port ISO 11926-1 –
162.4 ± 1.0
∅28.0 max. clearance dia for fitting
after filtering
[6.394 ± 0.039]
W
Y
View
254.415 ± 1.0
[10.016 ± 0.039]
F
254.415 ± 1.0
[10.016 ± 0.039]
257.115 ± 1.0
[10.123 ± 0.039]
Shaft L
c
Please contact Danfoss representative for specific installation drawings.
/
-20
7
16
Charge pressure port
Port ISO 11926-1 –
/
-24
5
16
Approximate center
of gravity
/
-18
9
16
System B gauge port "MB"
Port ISO 11926-1 –
/
9
∅ 28.0 max. clearance dia for fitting
Charge pressure port
Port ISO 11926-1 –
/
-24
5
16
F
E
E
Charge filtration port "F"
Port ISO 11926-1 – 1
∅ 42.0 max. clearance dia for fitting
to filter
Charge filtration port "E"
Port ISO 11926-1 – 1
∅ 42.0 max. clearance dia for fitting
from filter
F-F
Shaft L
c
Z
View
149.98 ± 1.0
121.89 ± 2.0
[4.799 ± 0.079]
[5.905 ± 0.039]
1.0
[0.04]
-18
16
/
-12
1
16
/
-12
1
16
G-G
106.5 ± 0.2
[4.193 ± 0.008]
BC00000198en-US0901 | 57
Shaft L
c
P003 395E
Need help?
Do you have a question about the H1 Series and is the answer not in the manual?
Questions and answers