Secure the unit..................................... 5 Safety Precautions....................................5 Unintended machine movement............................6 Flammable cleaning solvents..............................6 Fluid under pressure.................................. 6 Personal safety..................................... 6 Symbols used in Danfoss literature............................7 Design........................................7 The System Circuit....................................8 Operation Pressure Limiter Valves................................11 High Pressure Relief Valve (HPRV) and Charge Check...................... 11 Bypass Function....................................12...
A worldwide network of Danfoss Authorized Service Centers is available for major repairs. Danfoss trains and certifies Authorized Service Centers on a regular basis. You can locate your nearest Authorized Service Center using the distributor locator at www.Danfoss.com.
The legend above defines each symbol and explains its purpose. Design Danfoss H1 closed circuit piston pumps convert input torque into hydraulic power. The input shaft transmits rotational force to the cylinder block. Bearings at the front and rear of the pump support the shaft.
The minimum temperature relates to the physical properties of component materials. Size heat exchangers to keep the fluid within these limits. Danfoss recommends testing to verify that these temperature limits are not exceeded. Viscosity For maximum efficiency and bearing life, ensure the fluid viscosity remains in the recommended range.
Main pressure ports: SAE straight thread O-ring boss Remaining ports: SAE straight thread O-ring boss Recommended installation position Pump installation recommended with control position on the top or side. Consult Danfoss for non conformance to these guidelines. The housing must always be filled with hydraulic fluid.
Change filters with the fluid or when the filter indicator shows it’s necessary. Replace all fluid lost during filter change. For detailed filtration information, see Danfoss publication 520L0463 Fluids and Filtration. For information on biodegradable fluids see Danfoss publication 520L0465 Biodegradable Hydraulic Fluids.
Control orifices are blocked. Clean control orifices. Pump control screens Control screens are blocked. Replace control screens. Only a Danfoss Authorized Service Center may remove the unit’s endcap without voiding the warranty. Bypass function open If bypass function is open, the system loop will be Close bypass valves.
Control orifices are plugged. Clean control orifices. orifices Contaminated control EDC supply screen is plugged. Replace control screens. Only a Danfoss Authorized Service screens Center may remove the unit’s endcap without voiding the warranty. Pump inlet vacuum Inlet vacuum is too high resulting in reduced system Measure charge inlet vacuum.
Check for torn/missing servo seals. Replace and retest. Only decaying stroking the pump. a Danfoss Authorized Service Center may remove the servo piston without voiding the warranty. Bypass function open Open bypass will cause one or both directions to be Close bypass function.
Page 68
Phone: +86 21 3418 5200 Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products already on order provided that such alterations can be made without changes being necessary in specifications already agreed.