Pattern Generator Device Commands - Keysight Technologies N4960A User Manual

Serial bert 17 and 32 gb/s
Table of Contents

Advertisement

Remote Operation

6.12 Pattern Generator Device Commands

166
Jitter and spread spectrum clock can only be set using the N4960A serial BERT
controller clock SCPI commands. Therefore, SCPI values must be set to half of
the value desired on the pattern generator outputs.
Commands for controlling a pattern generator are preceded by :PG. However,
legacy commands preceded by :PG17 or :PG32 are supported but not
recommended.
Commands can be sent to a pattern generator currently connected to channel 0
(Jitter), channel 1 (Delay), or both. Refer to
Channelization
for information about how to send commands to the intended
pattern generator.
Command
:PG:DATA:DEEMphasis:POST1
Description
Set the 5-tap data de-emphasis POST1 cursor from 0 to −30 dB in 0.1
dB increments. The optional unit is dB. This command applies to the
N4951B-D17/-D32 only.
Example
:PG:DATA:DEEM:POST1 −3 (@ 0)
Sets the postcursor 1 to −3 dB for the pattern generator connected to
channel 0 (Jitter) only.