Keysight Technologies N4960A User Manual page 142

Serial bert 17 and 32 gb/s
Table of Contents

Advertisement

Remote Operation
142
Command
:OUTJitter:JITTer:SINusoidal2:FREQuency
Description
Set the SJ2 frequency from 1 Hz to 200 MHz in 1 Hz increments. This is
the over-programming range. Refer to
the maximum specified range. The optional units are Hz, kHz, MHz, and
GHz. The default value/unit is 10000000 Hz.
Example
:OUTJ:JITT:SIN2:FREQ 100MHz
Command
:OUTJitter:JITTer:SINusoidal2:FREQuency?
Description
Return the value of the SJ2 frequency. The range is 1 Hz to 200 MHz.
This is the over-programming range. Refer to
Specifications
for the maximum specified range.
Example
:OUTJ:JITT:SIN2:FREQ?
100000000 Hz
5 Performance Specifications
5 Performance
Keysight N4960A Serial BERT 17 and 32 Gb/s User Guide