ABB REACT-3.6-TL Product Manual page 124

From 3.6 to 4.6 kw, solar inverters
Hide thumbs Also See for REACT-3.6-TL:
Table of Contents

Advertisement

System
> Statistics
> Self consumpti.
> Self sufficien.
> Ener. from grid
> Ener. to grid
> Ener. to load
> PV en. to load
> PV ener.
> Settings
Password 0000
> Set time
> Set cash
> Set RS485 com
> Country Select
> New password
> Info
> SD Update Info
> Energy Policy
> Measures
6. PV en. to load
This section of the menu displays the statistics relating to the photovol-
taic energy used to fulfil the requests from residential loads. In particular:
• E-day: photovoltaic energy used for residential loads today
Inverter
• E-7d: photovoltaic energy used for residential loads in last 7 days
• E-30d: photovoltaic energy used for residential loads in last 30 days
• E-365d: photovoltaic energy used for residential loads in last 365 days
> Statistics
• E-tot: total photovoltaic energy used for residential loads
> Lifetime
7. PV ener.
> Partial
This section of the menu displays the statistics relating to the photovol-
> Today
taic energy produced. In particular:
• E-day: photovoltaic energy produced today
> Last 7 days
• E-7d: photovoltaic energy relating to last 7 days
> Last 30 days
• E-30d: photovoltaic energy relating to last 30 days
• E-365d: photovoltaic energy relating to last 365 days
> Last 365 days
• E-tot: total photovoltaic energy produced
> User Period
If the input channels are configured to be independent, the above-men-
> Settings
tioned parameters will be displayed for each of the two input channels
(CH1 and CH2)
Password 0000
> Vstart
System > Settings
> Input mode
Selecting Settings brings up the first screen relating to the password.
> Input UV Delay
The default password is "0000".
> Service
> Remote ON/OFF
Enter the password using the keys on the display:
• DOWN scrolls down the numerical scale (from 9 to 0)
> MPPT Scan
• UP scrolls up the numerical scale (from 0 to 9)
*
• ENTER confirms and moves to next digit
> Power Limit.
• ESC returns to the previous digit (from right to left)
> Reactive Power
• Press ESC several times to return to the previous menus
> Autotest
1. Set Time
> Alarms
Allows you to set the current date and time (not counting summer time)
> Backup
> Info
2. Set Cash
This section of the menu allows you to set the name of the currency and
> Part No.
the value given to 1 kWh of energy produced. Setting these parameters
> Serial No.
correctly allows the actual earnings/savings achieved by the system to
be displayed.
> Firmware
• Currency: sets the desired currency (default is Euro)
• Curr/KWh: indicates the cost/incentive of 1 KWh expressed in the cho-
sen currency (default is 0.50).
- 124 -
Скачано с сайта интернет магазина https://axiomplus.com.ua/
Display
> Settings
Password 0000
> Backlight
> Contrast
> Buzzer
> Power Graph
> Language
**
7 - Operation
****
Meter
> Settings
Password 0000
> Meter model
> Meter Address
> Meter com
> Info
> Type
> Part No.
> Serial No.
> FW Rel.
> Measures
> Voltage
> Active Power
> Line current
> Load current
> Frequency