ABB REACT-3.6-TL Product Manual page 130

From 3.6 to 4.6 kw, solar inverters
Hide thumbs Also See for REACT-3.6-TL:
Table of Contents

Advertisement

Inverter
cs
> Statistics
nsumpti.
> Lifetime
fficien.
> Partial
om grid
> Today
grid
> Last 7 days
load
> Last 30 days
to load
> Last 365 days
.
> User Period
> Settings
0000
Password 0000
e
> Vstart
h
> Input mode
85 com
> Input UV Delay
Select
> Service
sword
> Remote ON/OFF
> MPPT Scan
*
te Info
> Power Limit.
Policy
> Reactive Power
> Autotest
> Alarms
> Backup
> Info
> Part No.
> Serial No.
> Firmware
The table below shows the parameters which cannot be modified.
Parameter
Display
Set U>>
> Settings
Password 0000
Set U>
> Backlight
> Contrast
Set U> (10Min)
> Buzzer
> Power Graph
> Language
Set U<
Set U<<
Set F>>
Set F>
Set F<
**
Set F<<
Set Connect
Set Slow Ramp
- 130 -
Скачано с сайта интернет магазина https://axiomplus.com.ua/
****
Description
Grid over-voltage (OV) threshold (extended range):
Meter
En/Dis U>>. Enable/Disable the parameter
Value U>>. Set tripping value
Time U>>. Set tripping time
> Settings
Grid over-voltage (OV) threshold (restricted range):
En/Dis U>. Enable/Disable the parameter
Password 0000
Value U>. Set tripping value
Time U>. Set tripping time
> Meter model
Grid over-voltage (OV) threshold (average grid voltage value):
> Meter Address
En/Dis U> (10min). Enable/Disable the parameter
En/Dis U> (10min)d. Enable/Disable the derating on this
> Meter com
parameter
> Info
Value U> (10min). Set tripping value
Grid under-voltage (UV) threshold (restricted range):
> Type
En/Dis U<. Enable/Disable the parameter
Value U<. Set tripping value
> Part No.
Time U<. Set tripping time
> Serial No.
Grid under-voltage (UV) threshold (extended range):
En/Dis U<<. Enable/Disable the parameter
> FW Rel.
Value U<<. Set tripping value
Time U<<. Set tripping time
> Measures
Grid over-frequency (OF) threshold (extended range):
> Voltage
En/Dis F>>. Enable/Disable the parameter
Value F>>. Set tripping value
> Active Power
Time F>>. Set tripping time
> Line current
Grid over-frequency (OF) threshold (restricted range):
En/Dis F>. Enable/Disable the parameter
> Load current
Value F>. Set tripping value
Time F>. Set tripping time
> Frequency
Grid under-frequency (UF) threshold (restricted range):
En/Dis F<. Enable/Disable the parameter
Value F<. Set tripping value
Time F<. Set tripping time
Grid under-frequency (UF) threshold (extended range):
En/Dis F<<. Enable/Disable the parameter
Value F<<. Set tripping value
Time F<<. Set tripping time
Set U>Connect. Max. permissible voltage during checks
prior to grid connection
Set U<Connect. Min. permissible voltage during checks
prior to grid connection
Set F>Connect. Max. permissible frequency during
checks prior to grid connection
Set F<Connect. Min. permissible frequency during checks
prior to grid connection
Set Time con. Grid control interval before connection
Set T GridFault. Grid control interval before connection
following a grid fault
Enables gradual ramping up of power after the grid con-
nection.
7 - Operation
****
Battery
> General
> Settings
Password 0000
> Battery Mode
> Battery Pack
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
> SOH
> RT
> Pack 1
> Statistics
> Energy discha
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Settings
Password 0000
> Pack 1 enabl
> Smoke Sensor
> Info
> Device Name
> Serial No.
> FW Rel.
> Nom. Capacit

Advertisement

Table of Contents
loading

This manual is also suitable for:

React-4.6-tl

Table of Contents