Advertisement

5 - Installation
3. MULTICONTACT MC4 quick-fit connectors
Installation of Multicontact MC4 connectors requires crimping to be carri-
ed out with suitable equipment.
- Strip the cable to which you want to apply the connector (after verifying
that it complies with the connector limits).
2
4...6mm
- Apply the terminal to the conductor using the designated pliers.
5.5...9mm
Multi-Contact
32.6020-19100
- Insert the cable with the terminal into the interior of the connector, until
you hear the click indicating that the terminal is locked inside the con-
nector.
Click
- Firmly tighten the cable gland using the relevant tool to finish the ope-
ration.
Multi-Contact
32.6024
2.5 Nm
- 88 -