8. Reactive Power
This section of the menu may be used to manage the supply of reactive
power into the grid. There are 5 possible types of management:
• No Regulation: no regulation of reactive power. To activate this mode,
Display
press ENTER and then press ENTER to confirm.
• Cos-phi fixed: Sets the power factor to a fixed value. To activate this
> Settings
mode, press ENTER and set the Cos-Phi value to Over excited or Under
excited, from 1.000 to 0.800; press ENTER to confirm.
Password 0000
• Q fixed: Sets the reactive power to a fixed value. To enable this mode,
> Backlight
select Enable and then OK (using the UP / DOWN arrows). When ena-
> Contrast
bled, Set value will appear on the display, allowing you to set the value of
the reactive power (as either Over or Under excited, from 1.000 to 0.001)
> Buzzer
• Cos-phi = f(P): Power factor as a function of the active power supplied
> Power Graph
by the inverter. To enable this mode, select Enable and then OK (using
> Language
the UP / DOWN arrows). When it has been enabled, Load std curve will
appear on the display, allowing you to set the following regulation curve:
Cos-phi (Over excited)
0.85
0.9
0.95
1
0.95
0.9
0.85
Cos-phi (Under excited)
0.20
.3
The curve can be modified using the Aurora Manager Lite setup software
• Q = f(U): reactive power as a function of the grid voltage measured by
the inverter. To enable this mode, select Enable and then OK (using the
UP / DOWN arrows). When it has been enabled, Load std curve will
appear on the display, allowing you to set the following regulation curve:
**
Q/Pn
0.36
0.3
0.2
0.1
0
-0.1
-0.2
-0.3
-0.36
210
The curve can be modified using the Aurora Manager Lite setup software
- 132 -
Скачано с сайта интернет магазина https://axiomplus.com.ua/
****
Meter
> Settings
Password 0000
> Meter model
> Meter Address
> Meter com
> Info
> Type
> Part No.
> Serial No.
> FW Rel.
> Measures
> Voltage
> Active Power
> Line current
0.4
0.50
0.6
.7
> Load current
> Frequency
220
230
7 - Operation
****
Battery
> General
> Settings
Password 0000
> Battery Mode
> Battery Pack
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
P/Pn
> SOH
0.8
0.9
1
> RT
> Pack 1
> Statistics
> Energy discha
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Settings
Vout
250
240
Password 0000
> Pack 1 enabl
> Smoke Sensor
> Info
> Device Name
> Serial No.
> FW Rel.
> Nom. Capacit