This means that during the absence of grid voltage (display message
"Missing Grid") the alarm contact remains in its resting position.
• Crepuscular (display text "Crepuscular")
Display
Vin > Vstart
Relay State: Switched
> Settings
Password 0000
Vin < Vstart
> Backlight
Relay State: Idle
> Contrast
GRID RECONNECTION
t=based on Country Standard
> Buzzer
Relay State: Idle
> Power Graph
> Language
Vin
Yes
IS STILL LESS THAN
Vstart
• Alarm Latch (display text "Alarm Latch")
INVERTER RUN
Relay State: Idle
ERROR OCCURENCY
ERROR MESSAGE
t=15s
Relay State: Switched
GRID RECONNECTION
t=based on Country Standard
**
Relay State: Switched
ERROR
Yes
STILL
PRESENT
Alarms for which the relay is activated
E001
E002
E007
E009
E014
E015
E020
E021
E026
E027
E032
E033
E046
E050
E057
E058
E089
W003
- 136 -
Скачано с сайта интернет магазина https://axiomplus.com.ua/
****
Meter
The relay is activated (status: switched)
as soon as the inverter input voltage
N.C.
exceeds the activation voltage set.
N.O.
> Settings
Password 0000
The relay is in its rest position when the
N.C.
input voltage drops below 70% of the acti-
> Meter model
N.O.
vation voltage set.
> Meter Address
> Meter com
This mode is useful for disconnecting any
N.C.
output transformers that could have unne-
> Info
N.O.
cessary consumption during the night.
> Type
No
> Part No.
> Serial No.
> FW Rel.
> Measures
N.C.
> Voltage
N.O.
The relay is activated (status: switched)
> Active Power
whenever an error (code Exxx) or a
> Line current
warning (code Wxxx) is present (see
the table below). The contact returns to
> Load current
its resting position when the inverter re-
> Frequency
turns to its normal operating state and
N.C.
reconnects to the grid.
N.O.
N.C.
N.O.
No
E003
E004
E010
E011
E016
E017
E022
E023
E028
E029
E034
E035
E053
E054
E077
E078
W004
W005
7 - Operation
****
Battery
> General
> Settings
Password 0000
> Battery Mode
> Battery Pack
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
> SOH
> RT
> Pack 1
> Statistics
> Energy discha
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Settings
E005
E006
E012
E013
Password 0000
E018
E019
> Pack 1 enabl
E024
E025
E030
E031
> Smoke Sensor
E036
E037
> Info
E055
E056
E081
E084
> Device Name
W006
W007
> Serial No.
> FW Rel.
> Nom. Capacit