ABB REACT-3.6-TL Product Manual page 131

From 3.6 to 4.6 kw, solar inverters
Hide thumbs Also See for REACT-3.6-TL:
Table of Contents

Advertisement

Inverter
tics
> Statistics
onsumpti.
> Lifetime
ufficien.
> Partial
from grid
> Today
to grid
> Last 7 days
to load
> Last 30 days
to load
> Last 365 days
r.
> User Period
gs
> Settings
d 0000
Password 0000
me
> Vstart
sh
> Input mode
S485 com
> Input UV Delay
y Select
> Service
ssword
> Remote ON/OFF
> MPPT Scan
*
ate Info
> Power Limit.
Policy
> Reactive Power
es
> Autotest
> Alarms
> Backup
> Info
> Part No.
> Serial No.
> Firmware
Parameter
Display
Set F Derating
> Settings
Password 0000
Set VRT
> Backlight
> Contrast
Set FRT
> Buzzer
Set Backup
> Power Graph
> Language
Reset Latch
5. Remote ON/OFF
This section of the menu is used to enable / disable connection/discon-
nection of the inverter from the grid using the special control signal (REM).
• Disable: the connection/disconnection of the inverter to/from the grid is
dictated by the input (voltage from the photovoltaic generator) and output
(grid voltage) parameters of the inverter.
• Enable: connection/disconnection of the inverter to/from the grid is dic-
tated (as well as by the inverter input - voltage from photovoltaic genera-
tor - and output parameters - grid voltage) by the state of the remote On/
Off signal.
6. MPPT Scan
This section of the menu allows you to set the parameters of the maxi-
mum power point search (MPPT) function. This function is useful when
there are areas of shade on the PV generator, which may create several
**
points of maximum power on the operating curve.
• E/D MPPT Scan: Enables/Disables the scan for identifying the maxi-
mum power point of the system.
• Scan Interval: This section allows you to set the time between scans.
Remember that the shorter the scan interval the greater the loss of pro-
duction, due to the fact that energy is transferred to the grid during the
scan but not at the maximum power point. Each scan takes 2 seconds.
7. Power Limit.
This section of the menu allows you to adjust the limit to the active power
that the inverter can feed into the grid by setting the percentage of nomi-
nal power at which the limit should be triggered.
Setting it to 100% resets the default maximum power, which in some
installation country standards may be 110% of nominal power
- 131 -
Скачано с сайта интернет магазина https://axiomplus.com.ua/
Description
F Der. Mode. Select power derating in the event of grid
****
over-frequency.
F Der. Res. T. Time period after OF derating in which the
Meter
inverter checks that the frequency is back within the opera-
ting ranges (parameters "F<Connect" "F>Connect") requi-
red by the grid standard before ramping up the output from
the derating condition.
> Settings
F Der. Del. T. Setting deliberate delay before going into
derating
Password 0000
Set Zero P Th. Sets the voltage threshold at which the
> Meter model
inverter interrupts the export of energy to the grid.
Set Zero P Th. Sets the frequency threshold at which the
> Meter Address
inverter interrupts the export of energy to the grid.
> Meter com
Allows the Stand Alone accessory board to be enabled/
disabled. Once this mode is enabled, the guided setup will
> Info
automatically start.
Allows the active alarms preventing the system from ope-
> Type
rating (Latch) to be reset manually
> Part No.
> Serial No.
> FW Rel.
> Measures
> Voltage
> Active Power
> Line current
> Load current
> Frequency
7 - Operation
****
Battery
> General
> Settings
Password 000
> Battery Mo
> Battery Pa
> Info
> Nom. Cap
> Measures
> Ibat
> Vbat
> Pbat
> RE
> SOC
> SOH
> RT
> Pack 1
> Statistics
> Energy disc
> E-day
> E-7d
> E-30d
> E-365
> E-tot
> Settings
Password 000
> Pack 1 ena
> Smoke Sens
> Info
> Device Nam
> Serial No.
> FW Rel.
> Nom. Capac