ABB REACT-3.6-TL Product Manual page 160

From 3.6 to 4.6 kw, solar inverters
Hide thumbs Also See for REACT-3.6-TL:
Table of Contents

Advertisement

- Error code
- Error message
Name of Alarm and Cause
- Warning
Error in the check of Pin vs Pout:
E058
The error occurs if the difference between the
- Pin vs Pout check
measured value of input power and that of output
error
power is greater than the limit imposed internally to
-
Yellow LED
the inverter.
Emergency (stop) button activated:
This code marks the activation of the emergency
E065
button (button pressed). This warning is activated only
- Stop Button
where there is DC or AC voltage as, if the emergency
-
Yellow LED
button is pressed while it is operating only by battery,
it causes the whole system to shut down.
Error in the "Charger" circuit:
E066
- Charger-Bulk
Error internal to inverter relating to the bulk voltage of
-
Yellow LED
the circuit linked to battery charger
Overvoltage of "battery charger"
("Charger" circuit):
E067
- Charger - OV
Error inside the inverter. The alarm is raised when
-
Yellow LED
the battery charger voltage exceeds the overvoltage
threshold (internal unchangeable threshold).
Overcurrent of "battery charger"
E068
- Charger - OC
("Charger" circuit):
-
Yellow LED
Error inside the inverter.
E069
Error internal to inverter linked to the battery pack
- Charger-SlowRamp
charger circuit ("Charger" circuit"):
-
Yellow LED
E070
- Charger-preChar.
Error inside the inverter.
-
Yellow LED
Communication error inside the inverter:
E074
The alarm occurs when there are communication
- Internal error
problems between the control devices inside the
-
Yellow LED
inverter.
E077
Error in the system configuration:
- Internal Error
Error inside the inverter
-
Yellow LED
E078
Riso test error:
- Riso Test fail
Problem detected during the Riso test phase.
-
Yellow LED
E079
Incorrect Phases connection
- Wrong Sequence
(Only triphase models) The phases have not been
-
Yellow LED
connected correctly to the AC output
- 160 -
Скачано с сайта интернет магазина https://axiomplus.com.ua/
Solution
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Check that the emergency button has been pressed and if
necessary deactivate it.
- If the warning persists even though the button has been
deactivated, contact customer assistance.
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• The error might continue when the battery is disconnected
(e.g. activation of emergency button).
• If the message persists and is not linked to the battery being
disconnected, contact customer assistance.
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Error inside the inverter probably linked to the fuse in the
damaged battery pack; the error cannot be verified externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Error inside the inverter and cannot be checked externally.
- If the problem persists (once the inverter has been switched
off and back on again), contact customer assistance.
• Invert two of the phases of the grid wiring to the AC terminal
block of the inverter.
8 - Maintenance