ABB REACT-3.6-TL Product Manual page 23

From 3.6 to 4.6 kw, solar inverters
Hide thumbs Also See for REACT-3.6-TL:
Table of Contents

Advertisement

Photovoltaic inverter with integrated charger
Back-up output protection
Maximum AC overcurrent protection
Operating performance
Maximum efficiency (ηmax)
Weighted efficiency (EURO/CEC)
Typical battery efficiency (full cycle)
Communication
Remote monitoring
Wireless local monitoring
User interface
Wired local monitoring
Environmental
Ambient temperature
Optimal operating temperature for battery
Operating temperature for battery - charge
Operating temperature for battery - discharge
Relative humidity
Noise emission pressure, typical
Maximum operating altitude without derating
Recommended location
Physical
Degree of environmental protection
Cooling system
Size (H x W x D), equipped with 1 REACT-BATT-AP1
Weight (REACT-UNO and REACT-BATT-AP1)
Assembly system
Safety
Insulation level
Marking
Safety and EMC Standards
Grid Standard
(check availability through the sales channel)
Other characteristics
Load management
AC back-up output, off grid
Grid support
1) The output voltage range may vary according to the grid standard of the country of installation
2) The output frequency range may vary according to the grid standard of the country of installation
3) The IP54 protection level is guaranteed by complying with the indications set out in this manual and listed here below:
• in regard to covers, by complying with the prescribed tightening torques;
• in regard to connectors
,
46
47
• in regard to the cable glands
The connectors to the battery pack are excluded from the assessment of the IP54 protection level (
protection of a minimum of IP21 is required.
In regard to the connectors to the battery pack, the IP protection is provided by the battery pack box itself. Using the RECAT-BATT-
AP1 battery pack with the IP21 protection level, the protection level of the whole system becomes IP21.
4) Please refer to the document "String inverters – Product manual appendix" available at www.abb.com/solarinverters for information
on the quick-fit connector brand and model used in the inverter.
5) Optional
Note. Characteristics not specifically mentioned in this data sheet are not included in the product
,
, through use of the available counterparts;
52
,
,
, following the prescriptions indicated in this manual during installation.
48
49
51
Скачано с сайта интернет магазина https://axiomplus.com.ua/
REACT-UNO-3.6-TL
Integrated Wi-Fi datalogger
Wi-Fi with UI webserver, mobile APP
Mobile APP, UI Webserver, Graphic display
PVI-USB-RS232_485 (opt.)
5...95% without condensation
(when used without battery 4...100% condensing)
2000 m / 6560 ft
Internal with ventilation
IP54 (REACT-UNO), IP21 (REACT-BATT-AP1)
740 mm x 985 mm x 231 mm
Transformerless
IEC/EN62109-1, IEC/EN62109-2, EN61000-6-2,
EN61000-6-3, EN61000-3-2, EN61000-3-3,
EN61000-3-11, EN61000-3-12
CEI 0-21, DIN V VDE V 0126-1-1, VDE-AR-N 4105,
G83/2, G59/3, VFR2014, 4777.2:2015
Yes, through load manager box
Yes, automatic or manual restart in the case of no grid
Yes, where required by the regulations
- 23 -
2 - Characteristics
REACT-UNO-4.6-TL
16 A
97.1%
96.6% / -
94.0%
-20...+55°C
+5...+35°C
0...+40°C
-10...+45°C
50dB @ 1m
Natural
< 67 kg
Wall bracket
CE
,
,
), for which external
39
35
38
3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

React-4.6-tl

Table of Contents