Extron electronics SME 211 User Manual page 72

Streaming av product
Hide thumbs Also See for SME 211:
Table of Contents

Advertisement

X4(
= Greenwich Mean Time (GMT) offset
value: ‑12:00 to 14:00. Represents hours
and minutes (HH:MM) offset from GMT
including the time zone name.
X5)
= IP address in dotted decimal notation
(xxx.xxx.xxx.xxx)
Default IP address:
(no padding)
Default gateway IP address:
Default DNS server IP address:
X5!
= Subnet mask
Default:
255.255.0.0
X5@
= Hardware MAC address
(
00-05-A6-NN-NN-NN
X5#
= Time in 10s of milliseconds to wait for
characters coming into a serial port before
terminating (min = 0, max = 32767,
default = 10 = 100ms).
The response is returned with leading
zeros.
X5$
= Time in 10s of milliseconds to wait
between characters coming into a serial
port before terminating (min = 0, max =
32767, default = 2 = 20ms).
The response is returned with leading
zeros.
X5%
= Parameter to set either Length of message
to receive or Delimiter value.
L = 3 = byte count (min = 0, max =
32767, default = 0L = 0 byte count)
D = decimal value for ASCII character.
(min = 0, max = 00255, default =
00000L).
Value is placed prior to parameter:
3 byte length = 3L and ASCII 0A delimiter
is 10D. The parameter is case sensitive,
must use capital D or capital L. The
response is returned with leading zeros.
X5^
= Priority status for receiving timeouts:
0 = use Send data string command
parameters (if they exist [default]).
1 = use Configure receive timeout
command parameters instead.
X5&
= RS‑232 baud rate:
,
,
38400
57600
115200
X5*
= RS‑232 parity: Single letter:
Odd, Even, None (default), Mark, Space.
X5(
= RS‑232 data bits: 7, 8 (default)
X6)
= RS‑232 stop bits: 1 (default), 2
X6!
= Password: Maximum length 128
characters. All alpha‑numeric characters
permitted except
|
192.168.254.254
0.0.0.0
0.0.0.0
(no padding)
)
(default),
,
9600
19200
.
X6@
= Port timeout in tens of seconds (zero
padded. default: 00030 = 300 seconds.
Range = 1‑65000)
X6#
= Default name: Combination of model
name and last three pairs of MAC address
(example:
SME-211-07-8C-EC
X6$
= SNMP contact name text. Up to 64
alphanumeric characters, hyphens,
underscores, and period. (Default = Not
Specified)
X6%
= SNMP location. Up to 64 alphanumeric
characters, hyphens, underscores, and
period. (Default = Not Specified)
X6^
= SNMP public community string. Up to
64 alphanumeric characters, hyphens,
underscores, and period. (Default =
public)
X6&
= SNMP private community string. Up to
64 alphanumeric characters, hyphens,
underscores, and period. (Default =
private)
X6*
= Verbose mode
0 = Clear or none (Default for Telnet
host control)
1 = Verbose mode is on (Default for
RS‑232 and USB)
2 = Tagged responses for queries
3 = Verbose mode and tagged
responses for queries
X7)
= Text overlay window reference (currently
always 1)
X7!
= Text overlay visibility: 0 = Hidden (Default),
1 = Visible
X7@
= Text overlay mode: 0 = Technical data
(default), 1 = User text
X7#
= Text overlay string, 1‑255 ASCII printable
characters excluding "|"
X7$
= Text overlay font: User supplied and resid‑
ing in the /fonts folder or default
X7%
= Text overlay and text overlay background
color: Standard three pairs of hex digits
representing the RGB value
X7^
= Text overlay size:
25% (1.25% of screen height) to 400%
(15% of screen height) with 50% being
default at 2.5% of screen height
X7&
= Text overlay X position: Horizontal offset of
text box from left of image in pixels
X7*
= Text overlay Y position: Vertical offset of
text box from top of image in pixels
SME 211 • Remote Communication and Control
)
64