Mode Activation
1
Hold in the recessed rear
panel Reset button while
applying power to the unit.
NOTE: Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load
the most current firmware to the device.
4
Hold in the Reset button
until the reset LED flashes
four times. Then, release and
press Reset again within
1 second*.
5
Hold in the Reset button
until the reset LED flashes
three times. Then, release
and press Reset again
within 1 second*.
NOTE: *For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
SME 211 Series Reset Modes
Result
The SME 211 reverts to the factory
default firmware for a single power
cycle.
•
Sets port mapping back to factory
default.
•
Sets the IP address
back to factory default
(192.168.254.254).
•
Sets the subnet mask address
back to the factory default
(
).
255.255.0.0
•
Sets the gateway IP address to
the factory default (
Turns DHCP off.
•
•
The reset LED on the rear panel
of the unit flashes four times in
succession.
Performs a complete reset to factory
defaults (except the firmware).
•
Does everything mode 4 does.
Clears port configurations.
•
•
Resets all IP options.
Clears all user settings.
•
Clears all files from the unit.
•
The reset LED on the rear panel
of the unit flashes four times in
succession.
Purpose and Notes
Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise
with user-loaded firmware.
All user files and settings
are maintained.
Mode 4 is used to set
IP address information
using ARP and the MAC
address.
"Resetting IP Settings"
appears on a connected
display.
).
0.0.0.0
Mode 5 is useful to
start over with default
configuration and
uploading.
"Resetting SME 211"
appears on a connected
display.
Mode 5 is equivalent to SIS
command ZQQQ (see SIS
command
on page 68.
SME 211 • Introduction
Absolute reset
12