Communications

P680
Scom1 Act Value
Process data assignment for actual-value output over serial interface SST1.
*
Defines the parameter positions in the telegram.
Notes:
Word 1 should be assigned status word 1 (r552=r968).
The length (number of words) of the process data part in the telegram is set
with P686, Index i001.
i001=Word 01 of the (process data part of the) telegram
i002=Word 02 of the (process data part of the) telegram
...
i016=Word 16 of the (process data part of the) telegram
PNU=2A8Hex; Type=O2; Scaling: 1Hex
P681
Scom2 Act Value
Selection of the process data to be transmitted over serial interface SST2
*
(actual values) with peer-to-peer protocol selected (P688=1).
Defines the parameter positions in the telegram.
Notes:
The length (number of words) of the process data part in the peer-to-peer
telegram is set with P686, Index i003.
i001=Word 1 of the (process data part of the) telegram
i002=Word 2 of the (process data part of the) telegram
...
i005=Word 5 of the (process data part of the) telegram
PNU=2A9Hex; Type=O2; Scaling: 1Hex
P682
SCB Protocol
SCB can be operated as
*
master for the SCI boards or as
serial communications board
(see SCB manual).
0 = SCI-Module: Master for SCI boards
1 = 4 wire USS
2 = 2 wire USS
3 = Peer to Peer
4 = Option-1: not used
5 = Option-2; not used
Condition:
SCB board must be reported via P090 and 0P91, respectively
PNU=2AAHex; Type=O2; Scaling: 1Hex
P683
SCom/SCB BusAddr
Bus address of the serial communication interfaces
*
i001 = SST1: bus address of serial comm. interface 1 (CUR)
i002 = SCB: SCB baud rate, if P682=1, 2
PNU=2ABHex; Type=O2; Scaling: 1Hex
Siemens AG
6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit
Operating Instructions
AoteWell LTD
AoteWell Automation Sales Team
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
Buy Siemens PLC HMI Drives at AoteWell.com
Sales@aotewell.com
Value range
Display
[phys. unit]
Indices
Selection text
Factory-
setting
0 to 999
16
i001=968
i002=0
. . .
i016=0
0 to 999
5
i001=599
i002=34
i003=0
i004=0
i005=0
0 to 5
-
0
SCI-Module
4 wire USS
2 wire USS
Peer 2 Peer
Option 1
Option 2
0 to 30
2
0
https://www.aotewell.com
Parameter List
See
Modify
(access /
status)
3/
BR
3/
B
3/
BR
3/
B
3/ HBR
3/ H
3/
BR
3/
B
5-29

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents