https://www.aotewell.com
Maintenance
8.2.5
Replacing thyristor blocks
8.2.5.1
Disassembling the thyristor blocks for size H
8
7
7
G
G
K
K
9
G
12
K
13
8
Front thyristor block, level A (weight of a thyristor block, approx. 9.5 kg)
•
Swing out the two doors
•
d
Detach cable
from the modules and the screen fixture.
•
Remove 2 M6 hexagon-head bolts
•
Only on disassembling the central thyristor block, open 4 twisted cables
thermistors that are only located on the central thyristor block.
•
Unplug the gate and cathode cables (G, K)
•
Remove 3 M8 hexagon-head bolts
•
Loosen the two M8 hexagon-head screws
block out forwards.
•
A
Loosen M6 nut
and pull the thyristor block out upwards at an angle.
Rear thyristor block, level B (weight of a thyristor block, approx. 9.5 kg)
•
Unplug the gate and cathode cables(G, K)
•
Remove 3 M8 hexagon-head bolts
•
F
Loosen M6 nut
and pull the thyristor block out upwards at an angle.
The thyristor blocks are installed in the reverse order.
8-12
AoteWell LTD
AoteWell Automation Sales Team
8
13
7
7
12
G
G
G
K
K
K
9
9
G
G
12
12
10
K
K
8
8
13
13
a
by removing two M4 slit Torx screws
f
and swing out electronics box as far as the stop.
j
k
l
, push rail
S
D
.
Buy Siemens PLC HMI Drives at AoteWell.com
13
G
K
12
14
11
12
G
K
13
s
in each case.
.
;
approx. 150 mm upwards and swing the thyristor
.
Rectifier/Regenerating Unit
Sales@aotewell.com
8
G
K
7
5
6
5
9
10
8
g
h
and detach cable
Siemens AG
6SE7087-6AK85-1AA0
Operating Instructions
https://www.aotewell.com
09.02
2
1
2
4
3
2
1
2
for the two