Drive Data - Siemens Simovert 6SE70 Series Operating Instructions Manual

Master driver rectifier/regenerating unit sizes c to k
Table of Contents

Advertisement

https://www.aotewell.com
Parameter List
PNU
OP1S parameter name
Description
*
: Conf.
Par.
5.4

Drive data

P070
MLFB(6SE70 ... )
MLFB (order number) of the rectifier/regenerating unit
*
On POWER ON, the "Bootstrap" function is automatically selected as
long as P070 has not been set!
Enter the code of the corresponding MLFB here (see Section 4.3.9.2)
PNU=46Hex;
Type=O2; Scaling: 1Hex
P071
Line Volts
Line voltage of the rectifier bridge
*
RMS value of the rated voltage at which the power section is actually
operated
PNU=47Hex;
Type=O2; Scaling: 1Hex
P074
Limit LowVoltage
Response threshold for undervoltage disconnection and phase failure
monitoring and threshold for DC link voltage (ssee Section 4.3.10.1).
PNU=4AHex; Type=O2; Scaling: 1Hex
P075
Rtd Amps
Rated DC voltage of the R/R unit
*
Output DC current (average value) at the power terminals X1-C and X1-D.
PNU=4BHex; Type=O2; Scaling: 1Hex
P076
Config. PCircuit
Configuration of the power section
*
xx1
Motoring only
xx2
Motoring and generating possible
00x
No parallel power section connected
x1x to x2x
Number of additional parallel-connected power sections in
feed direction
0xx to 2xx
Number of additional parallel-connected power sections in
recovery direction
The number of parallel feed power sections must be greater than or equal to
the number of parallel recovery power sections:
Permitted configurations:
Feed power section(s):
Recovery power section(s):
Correction factor:
In recovery direction, calculation of the effective U d controller gain and
determination of the effective DC link capacitance for the load current
calculation take the above correction factor into account.
PNU=4CHex;
Type=L2;
5-8
AoteWell LTD
AoteWell Automation Sales Team
∧ 1
=
∧ 1
=
∧ 1
=
∧ 0.1
=
P076= 00x, 01x, 02x, 11x, 12x, 22x
E
EE
EEE
EE
R
R
R
RR
1
2
3
1
∧ 1
=
Scaling: 1Hex
Buy Siemens PLC HMI Drives at AoteWell.com
Value range
[phys. unit]
Selection text
0 to 120
100 to 1000
[V]
10 to 100
[% of P071]
or
[% of 1.35 * P071]
0.0 to 3276.7
[A]
001 to 222
EEE
EEE
RR
RRR
3/2
1
Siemens AG
Rectifier/Regenerating Unit
Sales@aotewell.com
09.02
Display
See
Indies
Modify
Factory-
(access /
setting
status
-
3/U BR
Depends on
3/U
unit
-
2/ ABR
acc. to P070
2/ A
-
2/
BR
61
2/
BR
-
2/U BR
acc. to P070
2/U
-
3/ ABR
002
3/ A
6SE7087-6AK85-1AA0
Operating Instructions
https://www.aotewell.com