Siemens Simovert 6SE70 Series Operating Instructions Manual page 181

Master driver rectifier/regenerating unit sizes c to k
Table of Contents

Advertisement

https://www.aotewell.com
09.02
PNU
OP1S parameter name
Description
*
: Conf.
Par.
r599
CW/SW 12-Pulse
Display of control/status word for 12-pulse mode, bit 0 to 15, see Section
3.8.4.
15
13
14
12
7
5
6
4
PNU=257Hex; Type=V2; Scaling: 1Hex
P600
Trg Bit Ready On
Destination of the status bit 'ready for turn ON' (status word 1, bit 0)
*
Power is ON, the drive may be turned on.
Depending on the selected index all settings according to Section 4.3.1.2
(process data wiring of the status word) may be selected.
i01:
GG:
i02:
SCI :
PNU=258Hex; Type=L2; Scaling: 1Hex
P601
Trg Bit Rdy Oper
Destination of the status bit 'Ready for operation' (status word 1, bit 1)
*
All the settings specified in Section 4.3.1.2 (process data wiring of the status
word) are permissible, depending on the index selected
Parameter values, indices: as P600
PNU=259Hex; Type=L2; Scaling: 1Hex
P602
Trg Bit Operat
Destination of the status bit 'Run' (status word 1, bit 2)
*
The unit is in operation.
Parameter values, indices: as P600
PNU=25AHex; Type=L2; Scaling: 1Hex
P603
Trg Bit Fault
Destination of the status bit 'Fault' (status word 1, bit 3)
*
Note:
For issuing the fault message via a terminal the active status (bit has H-
level) is inverted (broken wire proof).
Parameter values, indices: as P600
PNU=25BHex; Type=L2; Scaling: 1Hex
P604
Trg Bit No OFF2
Destination of the status bit 'No OFF2 command' (status word 1, bit 4)
*
Parameter values, indices: as P600
PNU=25CHex; Type=L2; Scaling: 1Hex
P606
Trg BitONblocked
Destination of the status bit 'Turn-ON locked' (status word 1, bit 6)
*
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=25EHex; Type=L2; Scaling: 1Hex
Siemens AG
6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit
Operating Instructions
AoteWell LTD
AoteWell Automation Sales Team
11
9
10
8
3
1
2
0
∧ 1
=
selection of a base drive terminal
selection of a SCI1/2 terminal
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
Buy Siemens PLC HMI Drives at AoteWell.com
Sales@aotewell.com
Value range
Display
[phys. unit]
Indices
Selection text
Factory-
setting
-
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
i001=1002
i002=0
0 to 4212
2
0
0 to 4212
2
0
https://www.aotewell.com
Parameter List
See
Modify
(access /
status)
2/
BR
3/
BR
3/
BR
3/
BR
3/
BR
2/
BR
2/
BR
2/
BR
2/
BR
3/
BR
3/
BR
3/
BR
3/
BR