Siemens Simovert 6SE70 Series Operating Instructions Manual page 149

Master driver rectifier/regenerating unit sizes c to k
Table of Contents

Advertisement

https://www.aotewell.com
09.02
Value
68
Overlap between CAN identifier PZD Receive-Multicast and PZD Receive-Internode
r731.002
Number of correctly received PZD CAN telegrams since Power ON
r731.003
Number of PZD telegrams lost since Power ON
Telegrams will be lost if the CAN Bus master sends PZD telegrams faster than they can be
processed by the slave.
r731.004
Counter of Bus Off states since Power ON (alarm A084)
r731.005
Counter of Error Warning states since Power ON (alarm A083)
r731.006
Status of the CAN controller
r731.007
Number of errors occurring during reception of PCD frames
r731.008
Type of error occurring during reception of PCD frames
r731.009
Value of error occurring during reception of PCD frames
r731.010
Number of correctly transmitted PZD CAN telegrams since Power ON
r731.011
Number of errors during transmission of PZD telegrams
PZD telegrams cannot be transmitted when the bus is overloaded
r731.012
Type of error occurring during transmission of PCD frames
r731.013
Value of error occurring during transmission of PCD frames
r731.014
Number of correctly processed PKW requests and responses since Power ON
r731.015
Number of PKW request processing errors, e.g. owing to bus overload or missing responses
from CUD1 (see below for error type)
r731.016
Type of PKW request processing error:
0
No error
9
Error transmitting the PKW response (while waiting for a free channel)
11
Timeout waiting for the PKW response from the CUD1
12
Timeout waiting for a free channel (bus overload)
r731.017
Value of error occurring while processing PKW requests
r731.018
Number of lost PKW requests
r731.026
Software version of CBC
(e.g. "12" = version 1.2, see also r720)
r731.027
Software identifier
(extended software version identifier, see also r722)
r731.028
Date of generation of CBC software
Day (H byte) and month (L byte)
r731.029
Date of generation of CBC software
Year
Fault and alarm messages:
Detailed information about fault messages can be found in Section 7.
Fault F080
An error occurred during initialization of the CBC board, e.g. incorrect setting of a CB parameter,
incorrect bus address or defective board.
Fault F081
The heartbeat counter (counter on CBC) which is monitored by SIMOVERT for "signs of life" from the
board has not changed for at least 800 ms.
Fault F082
Failure of PZD telegrams or a fault in the transmission channel.
Siemens AG
6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit
Operating Instructions
AoteWell LTD
AoteWell Automation Sales Team
Buy Siemens PLC HMI Drives at AoteWell.com
Meaning
Sales@aotewell.com
Start-Up
https://www.aotewell.com
4-67

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents