Siemens Simovert 6SE70 Series Operating Instructions Manual page 172

Master driver rectifier/regenerating unit sizes c to k
Table of Contents

Advertisement

https://www.aotewell.com
Parameter List
PNU
OP1S parameter name
Description
*
: Conf.
Par.
P323
Rel.RedCD V(Cur)
Release of current-dependent DC reduction
*
0:
current-dependent U d reduction blocked
1:
current-dependent U d reduction released
(see also P318, P321, P322)
PNU=143Hex; Type=02; Scaling: 1Hex
P329
PreCharge Time
DC link pre-charging time
RDS parameter
PNU=149Hex; Type=O2; Scaling: 1Hex
P330
Discharge Time
DC link discharge time
An even parameter value causes abrupt lowering. With effect from software
version 4.5, an odd parameter value causes the Ud setpoint to ramp down
with Ud reduction controlled by STW1, bit11 (see Section 4.3.1.1 and
4.3.10.2).
With the command OFF1 and current-dependent Ud reduction, P330 is
active in all cases.
RDS parameter
PNU=14AHex; Type=O2; Scaling: 1Hex
5-14
AoteWell LTD
AoteWell Automation Sales Team
∧ 1
=
∧ 1
=
∧ 1
=
Buy Siemens PLC HMI Drives at AoteWell.com
Sales@aotewell.com
Value range
Display
[phys. unit]
Indices
Selection text
Factory-
setting
0 to 1
-
0
0 to 9999
4
[ms]
500
0 to 9999
4
[ms]
2000
Siemens AG
6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit
Operating Instructions
https://www.aotewell.com
09.02
See
Modify
(access /
status)
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR