Siemens Simovert 6SE70 Series Operating Instructions Manual page 183

Master driver rectifier/regenerating unit sizes c to k
Table of Contents

Advertisement

https://www.aotewell.com
09.02
PNU
OP1S parameter name
Description
*
: Conf.
Par.
P618
Trg Current Lim.
Destination wiring of the status bit "Current limit active"
*
(status word 2, bit 18)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken-wire proof).
Parameter values, indices: as P600
PNU=26AHex; Type=L2; Scaling: 1Hex
P619
Trg Bit Ext Flt1
Destination of the status bit 'External fault 1' (status word 2, bit 19)
*
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=26BHex; Type=L2; Scaling: 1Hex
P620
Trg Bit Ext Flt2
Destination of the status bit 'External fault 2'
*
(status word 2, bit 20)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
If an ON command is active, L-level causes fault trip after 200 msec.
Parameter values, indices: as P600
PNU=26CHex; Type=L2; Scaling: 1Hex
P621
Trg Bit ExtWarn
Destination of the status bit 'External warning'
*
(status word 2, bit 21)
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=26DHex; Type=L2; Scaling: 1Hex
P622
Trg Bit i2t Inv
Destination of the status bit 'Warning unit overload'
*
(status word 2, bit 22);
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, indices: as P600
PNU=26EHex; Type=L2; Scaling: 1Hex
P623
Trg BitFltTmpInv
Destination of the status bit 'Fault unit overtemperature'
*
(status word 2, bit 23
Note:
For issuing the message via a terminal the active status (bit has H-level) is
inverted (broken wire proof).
Parameter values, Indices: as for P600
PNU=26FHex; Type=L2; Scaling: 1Hex
Siemens AG
6SE7087-6AK85-1AA0
Rectifier/Regenerating Unit
Operating Instructions
AoteWell LTD
AoteWell Automation Sales Team
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
∧ 1
=
Buy Siemens PLC HMI Drives at AoteWell.com
Sales@aotewell.com
Value range
Display
[phys. unit]
Indices
Selection text
Factory-
setting
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
0 to 4212
2
0
https://www.aotewell.com
Parameter List
See
Modify
(access /
status)
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
3/
BR
5-25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents