Processing Flow And Symbol Rate Calculation; Figure C-1. Slm-5650C/ Slm-5650C-Odu - Feature Block Diagram - Comtech EF Data SLM-5650C CyberLynx Installation And Operation Manual

Table of Contents

Advertisement

C.2

Processing Flow and Symbol Rate Calculation

The modem supports Ethernet interface and provides options for framing, modulation and
spreading. Figure C-1 shows the processing flow for these functions.
Figure C-1. SLM-5650C/ SLM-5650C-ODU – Feature Block Diagram
The symbol rate
FEC encoding, modulation, and transport overhead factors as shown in the equation
"S
=B
/M
C
F
R
R
O
R
Operands:
Operand 1 –
Operand 2 –
Operand 3 –
o
o
Only one of these two features (AUPC Mode or ACPC Mode) may be enabled
at any given time.
Operand 4 –
o
o
If the DSSS feature is enabled, then the simple equation for Chip Rate (SC)
equivalent to (Bw) of the spread signal is: "SC=K*SR" where 'K' is the
programmed spreading factor (e.g. 2, 4, 8, 16, 32, 64, up to 512)
Appendix C
S
(Carrier 3dB Bandwidth) is a function of the programmed data bit rate
R
(referred to hereafter as "Equation 1"), containing the following
F
F
"
RS
T
C
M
= Modulation Order
O
C
= Code Rate of the FEC (e.g., CR = 0.75 if stated FEC code rate = "3/4")
R
= AUPC Mode Framing Factor, where:
F
c
F
= 15/16 if AUPC Mode is enabled;
C
F
= 1 if neither feature is enabled.
C
F
= TRANSEC Framing Factor, where:
T
=
F
N*16/[N*16+3], where 'N' is the selected Frame Length in AES blocks per
T
frame, in the range of 1 to 16.
F
= 1 if the TRANSEC encryption is disabled.
T
SLM-5650C / SLM-5650C-ODU Satellite Modem
'1' if BPSK
'2' if QPSK
'3' if 8PSK
'4' if 16QAM
C–2
Revision 1
B
with
R