Command
Arguments for
Parameter
(Instruction
Command or
Type
Code and
Response to
Qualifier)
Query
Rx BERT
BTH=
1 byte
Sync Loss
Threshold
Rx Eb/No
N/A
4 bytes
Rx BERT
N/A
7 bytes
Errors
Rx BPSK
RBO=
1 byte
Data
Ordering
Rx Clock
RCI=
1 byte
Invert
Rx
RCW=
1 byte
Reed-
Solomon
Code Word
Serial Remote Control
Description of Arguments
Command or Query.
Rx BERT Sync Loss Threshold, where:
0=Low
1=Medium
2=High
Example: BTH=1 (Medium)
Query only.
Returns the value of Eb/No, between 0 and 20 dB, resolution = 0.1 dB.
Returns 99.9 if demod is unlocked.
Example: EBN=12.3 (selects Eb/No = 12.3 dB)
For values greater than 20.0 dB, the reply will be: EBN=+020
Query only.
Read the total number of Bit Errors.
Example: ERR=9999999
Command or Query.
Invert Receive BPSK Data Ordering in the form x, where:
0=Standard
1=Non-Standard
Example: RBO=1 (selects Inverted BPSK Ordering)
Command or Query.
Invert Receive Clock in the form x, where:
0=Normal
1=Inverted
Example: RCI=1 (selects Inverted RX Clock)
Command or Query.
Rx RS encoding in the form x, where:
0 = RS(225,205,10)
1 = RS(219,201,9)
2 = RS(208,192,8)
3 = RS(194,178,8)
4 = RS(126,112,7)
5 = RS(220,200,10)
Depending on Modem mode, overhead type, and data rate, not all selections will be valid.
Example: RCW=0 (This is a 'don't care' if RS is Off under TRS)
SLM-5650C / SLM-5650C-ODU Satellite Modem
7–19
Revision 1
Query
Response to
(Instruction
Response to
Command
Code and
Query
Qualifier)
BTH=
BTH?
BTH=x
BTH?
(see Description of
BTH*
Arguments)
BTH#
N/A
EBN?
EBN=xxxx
(see Description of
Arguments)
N/A
ERR?
N/A
RBO =
RBO?
RBO=x
RBO?
(see Description of
RBO*
Arguments)
RBO#
RCI =
RCI?
RCI=x
RCI?
(see Description of
RCI*
Arguments)
RCI#
RCW =
RCW?
RCW=x
RCW?
(see Description of
RCW *
Arguments)
RCW #