Description
Rx Misc
Circuit ID
Built-in BERT
Modem Configuration
BPSK Bit Order:
Match the BPSK Bit Order for the Tx and Rx. This is used for modem to modem
compatibility.
RxData Mask / Demod Faults Mask / Eb/No Alarms Mask:
Events for RxData, Demod Faults, and Eb/No Alarms can either be active or masked. The
events are not reported if masked.
RxData events can also be set to report all ones for no data.
Eb/No Alarm Point:
The Eb/No Alarm point can be set to a specific value to report an event if the Eb/No falls
below a desired value.
Modem Events are reported under the Status \ Event Log Tab. Click on the Code value to
read the event.
The modem operator can designate a Circuit ID for the modem. Use only numbers and
capital letters. Delete the dash characters before entering the Circuit ID.
The Tx or Rx can be turned on separately. The data pattern must match on the Tx and Rx
modems.
The Patterns are:
SLM-5650C / SLM-5650C-ODU Satellite Modem
Parameters
6–19
Revision 1
MN-SLM-5650C