Group 53: FBA Data Out
Code
5301
...
5310
Group 58: Drive EFB
The drive's Group 58 must be replicated on bypass, since the EFB link on the drive
is reserved for internal communication with the bypass. All Group 58 functionality
associated with selection by 98.02 is hosted on the bypass controller for drive.
Group 58 parameters on the bypass are a subset of the Group 58 parameters on the
drive.
Code
5802
5803
5804
5805
Name
Resolution
DATA OUT 1
1
...
DATA OUT10
Name
Resolution
DV PROT ID
hex
DV MAC ID
1
BAUD RATE
0.1 kbit/s
EFB PARITY
1
Group 53: FBA Data Out
Range
0 = Not In Use
1 = Control Word (ABBDP)
2 = Ref 1 (ABBDP)
3 = Ref 2 (ABBDP)
4 = Status Word (ABBDP)
5 = Actual Value 1 (ABBDP)
6 = Actual Value 2 (ABBDP)
0101h -063FFh = Drive
parameters
8101h - E3FFh = Bypass
parameters + 8000h
Group 58: Drive EFB
Range
Default
0x0000 - 0xFFFF
0x0000
0 - 65535
256
1.2, 2.4, 4.8, 9.6, 19.2,
9.6
38.4, 57.6, 76.8
0=8 NONE 1,
1=8 NONE 2,
2=8 EVEN 1,
3=8 ODD 1
Default
Description
Specifies information to be
written to the drive (out of
the network). Only for
modules that support the
cyclic low scanner function
(such as FMBT-12).
For specifying values 1-6,
select ABB drive's profile
information, like control
word of reference.
To specify drive
parameters, use the format
ggh.pph where gg
parameter group in
hexadecimal and pp
parameter in hexadecimal.
For instance, drive
parameter 30.14 is
encoded as 1E0Eh.
Bypass parameter is
specified as 8000h +
gg
.pp
. For instance,
h
h
bypass parameter 0114 is
encoded as 810Eh.
Description
Protocol ID and revision:
Format:
XXYY where XX = protocolID and
YY = program revision
Default value is protocol-
dependent: Modbus and N2 is 1,
BACnet is 128. Drive station ID
(NODE ADDRESS)
Refer to
Communication setup –
EFB
on page
79
for more
information.
Default value is protocol-
dependent: Modbus and N2 is
9.6, BACnet is 38.4. Defines the
communication speed of the
RS485 link in kbits per second
(kb/s).
Refer to
Communication setup –
EFB
on page
79
for more
information.
0
Defines the data length, parity and
stop bits to be used with the
RS485 link communication.
Default value is protocol-
dependent: Modbus is 1, N2 and
BACnet is 0. Refer to
Communication setup – EFB
page
79
for more information.