Appendix C
Default values and ranges
The default values and ranges represent the typical factory transmitter configuration.
Depending on how the transmitter was ordered, certain values may have been configured
at the factory and are not represented in the default values and ranges.
Table C-1:
Transmitter default values and ranges
Type
Parameter
Flow
Flow direction
Flow damping
Flow calibration factor
Mass flow units
Mass flow cutoff
Volume flow type
Volume flow units
Volume flow cutoff
Meter factors
Mass factor
Density factor
Volume factor
Configuration and Use Manual
Default
Range
Forward
(1)
0.8 sec
0.0 – 51.2 sec
1.00005.13
g/s
Sensor-specific
value set at
factory
Liquid
L/s
0/0 L/s
0.0 – x L/s
1
1
1
Default values and ranges
Comments
User-entered value is corrected
to the nearest valid value in list
of preset values.In Special mode,
the preset values are 1/5 nor-
mal. For gas applications, a mini-
mum value of 2.56 is recom-
mended. The 2.56 value will be
automatically rounded up to 3.2
seconds.
For sensors, this value repre-
sents the FCF and FT factors con-
catenated.
For most sensors, the typical set-
ting is 0.05% to 0.10% of the sen-
sor's rated maximum flow rate.
For some sensors, the setting
may be higher.
For some applications, such as
empty-full-empty batching, a
higher value is recommended.
Contact MMI customer service
for assistance.
x is obtained by multiplying the
flow calibration factor by 0.2, us-
ing units of L/s.
171