Connecting

5.7 Connecting the PROFINET strain relief

5.7
Connecting the PROFINET strain relief
The PROFINET strain relief supplied in the product package is used to prevent accidental
removal of the Ethernet cable and Industrial Ethernet FastConnect connector from the
device. You need two cable ties to use the strain relief.
To fix the PROFINET strain relief, you will need a TORX T10 screwdriver.
Steps for connecting the strain relief
1
2
5.8

Connecting the power plug locking mechanism

The power plug locking mechanism is part of the scope of supply and prevents the power
plug from being pulled out accidentally. The power plug locking mechanism is a metal
bracket that is screwed onto the computer housing.
You require a TORX T20 screwdriver for attaching it to the housing.
The power plug locking mechanism is a safety-relevant part. Read the information in the
chapter "Connecting the (120 V / 240 V AC) power supply".
52
Fasten the PROFINET strain relief
enclosure with two oval-head screws (M3 thread).
Connect network cable and attach to the strain relief
using cable ties
to the device
Operating Instructions, 04/2013, A5E02722710-04
SIMATIC HMI IPC677C