Page 1
SIMATIC IPC377E Preface Overview Safety instructions SIMATIC Installing and connecting the device Industrial PC SIMATIC IPC377E Commissioning the device and device functions Operating the device Operating Instructions Expanding and assigning parameters to the device Maintaining and repairing the device Technical specifications...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
The PDF version of the documentation is supplied with the device on the "Documentation and Drivers" CD/DVD. Conventions The terms "PC" or "device" are used in place of the product name SIMATIC IPC377E in these operating instructions. In these operating instructions, "Windows 7" is used as an abbreviation for "Windows 7 Ultimate".
Page 4
The following earlier release versions of these operating instructions have been published: Edition Comment 08/2017 First edition 11/2017 Operating system information has been replaced by references to separate operating system documents. 07/2018 Amendment to certification part. 06/2019 Update the Advanced menu for BIOS description. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Windows Security Center ....................... 37 Operating the device ..........................38 Operator input options ......................39 IPC calibration function ......................39 Operating the touch screen ....................40 Expanding and assigning parameters to the device ................41 SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 6
Currently allocated system resources ..................74 BIOS description ........................75 8.6.1 BIOS getting started ....................... 75 8.6.2 Main setup ..........................76 8.6.3 Advanced setup ........................78 8.6.4 Chipset setup ......................... 82 8.6.5 Security setup ........................83 SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 7
Markings and symbols .......................... 95 Overview ..........................95 Safety ............................95 Operator controls ........................95 Certificates, approvals and markings ..................96 Interfaces ..........................97 List of abbreviations ..........................98 Glossary ............................. 102 Index..............................110 SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● Compact design ● Rugged ● Maintenance-free operation possible SIMATIC IPC377E is available with various operating units that differ with regard to the display size. This display is a color display with a backlit "wide-screen" format TFT color display. Displays are available for the SIMATIC IPC377E: ●...
1.2.1 Views of the basic device Front and side view ① Display/touch screen ② Recesses for mounting clips Rear view ① Recesses hole for VESA mounting ② Cooling fin ③ Recesses for mounting clips SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Interfaces of the basic device ① Power status display ② HDD status display ③ On/off switch. ④ Connection for a 24 VDC power supply ⑤ Function earth ⑥ Connection for analog audio source and speaker ⑦ VGA interface SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
1.2.3 Status displays Display Meaning Description PC operating status display Hibernate, switched off or unplugged Green PC is in operation. Green flashing standby Display for hard disk access No accessing Green flashing Accessing data SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Page 13
Note that the device is classified as "Open Type" for use in the area of Industrial Control Equipment (UL61010-2-201). A UL61010-2-201 conform enclosure is therefore a mandatory requirement for approval or operation according to UL61010-2-201. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 14
• Replace the lithium battery only with an identical battery or types recommended by the manufacturer (type: CR2032). • For any requirements on product maintenance, contact Siemens Technical support. (Page 93) • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C, and...
• Always use suitable cleaning agents. Read the information about chemical resistance in the Internet, see "SIMATIC IPC after-sales information system (http://www.siemens.com/asis)". SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 16
A small number of defective pixels in the display is therefore unavoidable. This does not present a functional problem as long as the defective pixels are not bunched in one location. Additional information is available in the section "Technical specifications (Page 56)". SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Death or serious injury could occur. Make sure that the damaged device is not inadvertently installed and put into operation. Label the damaged device and keep it locked away. Send off the device for immediate repair. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
You can find this information on the product label and COA label. The product label is located on the back of the unit. The COA label is only available with pre-installed Windows operating systems and is affixed to the rear of the device. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 19
Microsoft Windows "Product Key" on the "Certificate Of Authenticity" (COA): The COA label is only attached to the rear of the device containing a preinstalled and activated Windows operating system. ● COA label of a device with Windows operating system SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
45 °C The device enclosure fulfills the requirement of a fire protection enclo- sure. ● Vertical installation in upright format, display turned through ±90 ° compared with the standard position SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● Permissible deviation from plane at the mounting cutout: ≤ 0.5 mm This condition must be fulfilled for the mounted device. ● Permissible surface roughness in the area of the seal: ≤ 120 µm (R 120) SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 22
The following table shows the dimensions of the required mounting cutout: Mounting cutout Device 12 Inch 15 Inch 19 Inch Width w 388.4 Height h 240.5 279.2 Width and height should be reversed accordingly when mounting in vertical format. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
UL61010-2-201. ● Provide adequate volume in the control cabinet for air circulation and heat transport. Keep at least 5 cm distance between the device and control cabinet. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
To achieve the degree of protection for the device, the positions for the mounting clips shown below must be adhered to. The positions of the mounting clips are marked by stamps on the cutouts. Fit the mounting clips in all the stamped cutouts. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 25
12" display 15" display 19" display Requirement ● All packaging components and protective films should be removed from the device. ● To install the panel, you need the mounting clips from the accessories kit. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 26
0.5 Nm. Repeat steps 2 and 3 for all mounting clips. Check the fit of the mounting seal. Result The device is mounted and the relevant degree of protection is ensured at the front. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Installing and connecting the device 3.2 Installing the device 3.2.3 Fastening a device using a VESA adapter You can also fasten the SIMATIC IPC377E using a VESA (Video Electronics Standards Association) adapter. Different models of VESA adapters are offered by third-party manufacturers. Note To meet UL requirements, the type of VESA adapter must be an UL1678 listed device.
Page 28
Tighten the screws with the following torques, which may not be exceeded. Adhere to the torque specifications of the third-party vendors: 1.5 Nm for connecting the device and the VESA mounting interface. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
• Always pull out the power plug when you are not using the device or if the device is defective. The power plug must be freely accessible. • Use a central power isolating switch for cabinet installation. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
• Never operate the device without function earth. • If a device is defective, remove it from operation without delay and label it accordingly. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● You are using the supplied terminal. ● A two-core cable with a cable cross-section of 0.75 mm to 2.5 mm for the 24 VDC connection. ● A slotted screwdriver with approx. 3 mm blade. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 32
You can use the integrated Ethernet interfaces (10/100/1000 Mbps) for communication and data exchange with automation devices, e.g. SIMATIC S7. You need a suitable software to use this functionality: STEP 7, WinCC, SIMATIC NET. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 33
Control level. Information on this can be found on the SIMATIC NET Manual Collection CD. The software package and the documentation are not included in the product package. Additional information You can find additional information on the Internet at: Technical support (https://support.industry.siemens.com/cs/?lc=en-WW) SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
The operating safety of the device and the plant is at risk. Do not switch off the device during the entire installation process. Do not change the default values in the BIOS setup. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● Select "Start" > "Shut down" ● Briefly press the on/off switch (unless otherwise configured in the power options). Information on the position of the button is available in the section "Interfaces of the basic device (Page 10)". SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 36
Data on the drive may be lost. The device may be damaged. Perform a hardware reset only in the case of an emergency. For all operating systems: ● Press the on/off switch for more than four seconds. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● Real-time protection (Windows 7 only): Windows Defender displays warnings if spyware or possibly unwanted software is installed or executed on the computer. You will also receive a warning if programs attempt to modify important Windows settings. Configure the Security Center according to your requirements. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Operating the device The device variants differ with regard to their dimensions and display size. The example in the following figure shows the front view of the 12" touchscreen variant. ① Display with touchscreen SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● Advanced touch features ● Calibrating This calibration function has three calibration methods: 4 points calibration, 9 points calibration and 25 points calibration. You can select any of them for calibrating as your request. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
● Using a silicone finger with a diameter of 1.6 cm: 50 g. Note Only touch one point on the touch screen and not several points at one time, as this may trigger unintended reactions. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
• You cannot set the device cover down because of the connecting cable of the drive. • You first have to pull out the connection plug in order to completely remove the device cover. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 42
For 15" and 19" devices, there are three cable • connectors: LVDS connector, power connector and touch connector. Remove the marked screws on the back of the panel PC. Hold the main machine and turn it back. Remove the marked screws. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Make sure that the maximum permissible ambient temperature of the Mini cards are specified accordingly. Note If you want to use both of the two slots, insert the half-size mini card first. Requirement ● The device is opened. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 44
Insert a full-size mSATA card or a mini card with USB2.0 inter- face into the slot. Secure the card with the screw that you removed from the card holder into the same hole. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 45
Follow the below instructions to set the antenna if your cards have an external antenna. Remove the flaps of the two holes with a screw driver. Secure the antenna in the device through the hole. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
RF suppression. Contact your technical support team or where you purchased your PC to find out which system expansion devices may be installed. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
You may possibly trigger unwanted actions of the device or controller that are liable to cause personal injury or damage to the machinery. Always cut off the power supply of the device before you clean it. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Recycling and disposal The devices described in these operating instructions can be recycled thanks to their low level of pollutants. Contact a certified disposal service company for environmentally sound recycling and disposal of your old devices. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
• Replace the lithium battery only with the type recommended by the manufacturer (type: CR2032). • For any requirements on product maintenance, contact Siemens Technical support (Page 93). • Do not throw lithium batteries into fire, do not solder on the cell body, do not recharge, do not open, do not short-circuit, do not reverse polarity, do not heat above 100°C and...
Read the information in section "Repair information (Page 46)". Requirement ● The device is open. ● A hard disk drive ● A T10 screwdriver SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Installing the software Information on installation of the operating system is available on the Internet and on the supplied DVD: Microsoft® Windows® 7 (https://support.industry.siemens.com/cs/ww/en/view/109752041) Microsoft® Windows® 10 (https://support.industry.siemens.com/cs/ww/en/view/109768887) Note Before installing Windows 10, set the boot mode and video as UEFI in BIOS. On how to set the boot mode and Video, refer to Boot Setup (Page 85).
4. Click Drivers to open the available OS list. 5. Click the OS you use. The available driver list opened. Alternative way to access the drivers Documentation and Drivers You can also find the drivers in the below path of the DVD. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 53
3. Click Yes to confirm the user account control question. 4. Click Next to continue. 5. Select the radio button before "I accept the terms in the license agreement", and click Next to accept license agreement. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 54
3. Click Yes to confirm the user account control question. 4. Click Next to continue. 5. Select the radio button before "I accept the terms in the License Agreement", and click Next to accept license agreement. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 55
The installation starts. 7. Click Next to continue. 8. Select the radio button next to “Yes, I want to restart my computer now.” and click Finish to restart the computer for the changes to take effect. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
ISO 9001 certificate The Siemens quality management system for all production processes (development, production and sales) meets the requirements of GB/T 19001-2008/ISO 9001:2008, ISO 14001:2004 + Cor. 1:2009 and BS OHSAS 18001:2007.
Page 57
Avis Canadian Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada. Responsible party for Supplier's Declaration of Conformity Siemens Industry, Inc. Digital Factory - Factory Automation 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 Mail to (amps.automation@siemens.com)
Page 58
바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. BSMI This product meets the requirements of CNS15663(102/07), CNS13438(095/06/01) generic standard. 警告使用者: 本產品是甲類的資訊產品,在居家的環境中使用時,可能會造成射頻干擾,在 這類情況下,使用者會被要求採取某些適當的對策。 WEEE label (European Union) Disposal instructions, observe the local regulations and the section "Recycling and disposal (Page 48) ". SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
The consequences are incalculable and range from unforeseeable malfunctions to a total failure of the machine or system. Avoid touching components directly. Make sure that persons, the workstation and the packaging are properly grounded. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 60
There is no equipotential bonding without grounding. An electrostatic charge is not discharged and may damage the ESD. Protect yourself against discharge of static electricity. When working with electrostatic sensitive devices, make sure that the person and the workplace are properly grounded. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 61
This way, the discharge energy does not reach and damage the sensitive components. – Discharge your body electrostatically before you take a measurement at a module. Do so by touching grounded metallic parts. Always use grounded measuring instruments. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
24 V, 1.9 A • • • The current may maximum current differ depending on the operating mode 2.5 A at 20.4 V • and extensions. Noise emission < 40 dB(A) according to DIN 45635-1 SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 65
2.24 GHz, 2 MB 2nd level cache, 6 W TDP Main memory DDR3L memory up to 8 GB, 1× SODIMM modules / non-ECC Expansion slots 1 Mini PCIe half-size slot • 1 mSATA slot with USB2.0 bus signal • SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 66
USB 2.0, high speed/high current, • USB 3.0, high current • You can find additional information in the section Power supply (Page 68). LAN interface X1 P1, Intel Ethernet Controller I211-AT RJ45 10, 100, 1000 Mbps SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
With hard disk : 10 to 58 Hz: 0.0375 mm • 58 to 200 Hz: 4.9 m/s² • With SSD : 10 to 58 Hz: 0.075 mm • 58 to 200 Hz: 9.8 m/s² • SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
24 VDC (20.4 to 28.8 VDC) Power consumption Max. 30 W Max. 35 W Max. 45 W Power failure buffering Hold-up time > 10 ms The performance specifications apply to the power supply component, but not to the device. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
2 × USB 2.0 Ethernet External 2 x RJ45 10/100/1000 Mbps DisplayPort External 1 x DP 1 x VGA Only two of these USB ports may be operated simultaneously in high current mode, max. 6 W. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Pin assignment RS422 Short description Meaning Transmit data - (O) for full-duplex mode Transmit data + (O) for full-duplex mode Receive data + (I) for full-duplex mode Receive data - (I) for full-duplex mode Signal ground SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Description WAKE# Signal for link 3.3 V 3.3 V power reactivation Reserved** Ground Reserved** 1.5 V 1.5 V power CLKREQ# Clock request UIM PMR Ground UIM DATA REFCLK- Reference clock UIM CLK (differential pair) SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Windows operating system, depending on the hardware equipment, drivers and connected external devices. You can view the current allocation of system resources or possible conflicts in the Control Panel. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
1. Power on the motherboard. 2. Press DELETE or ESC key on your keyboard during the Power - On - Self - Test (POST) when the SIEMENS logo is shown on screen. The Aptio TSE main BIOS setup menu is displayed.
You can press <Enter> Key to discard changes and exit. Or use arrow keys to select “No” then press <Enter> Key to abort this function and return to previous screen. 8.6.2 Main setup The main setup menu The main setup menu is shown as below. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 77
Access level shows what access right you have to setup BIOS. For setting the access level, go to the chapter Security Menu. Access right Description Administrator Have full access right to change BIOS settings. User Have guest level access right and can only change limited items. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
In USB configuration page, you can view and configure USB parameters. USB device The USB device shows the USB device detected by BIOS during POST. If there is no device attached to the motherboard, only 2 Hubs is shown. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 79
VCORE Show VCORE power voltage. +3.3V Show +3.3V power voltage. Show +5V power voltage. +12V Show +12V power voltage. VCC3V Show VCC3V power voltage. VSB3 Show VSB3 power voltage. VBAT Show VBAT power voltage. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 80
To enable RS-485 mode for serial port 1/2. See the baud rate for RS-422 and RS-485 below: 50, 75, 110,134.5, 150, 300, 600, 1200, 1800, 2000, 2400, 3600, 4800, 7200, 9600, 19200, 38400, 57600, 115200. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 81
You can enable or disable On Board X1 P1 Port with the following steps: 1. Select Disabled or Enabled as you need and press Enter key in the pop-up window. 2. Press F4 key and save the change. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
In Audio configuration page, you can view and configure Audio Controller. 1. Select Audio Controller with the arrow keys and press Enter key. 2. Select Enabled or Disabled as you want and press Enter key. 3. Press F4 key and save the change. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
After the passwords are set, you must enter a password every time when you enter BIOS. Select Security menu item in BIOS Setup screen to enter Security setup screen. Security menu is shown below: SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 84
3. Re-enter the password when you are asked to confirm the password in the screen popped up. Note Record the new password when the password is changed. If you forget the password, you must erase the system configuration information in NVRAM. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
See the quiet boot options below: Option Description Disabled Set the motherboard to display the POST message. Enabled Set the motherboard to display the SIEMENS logo. This is the default set- ting for Quiet boot. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 86
1. Select boot priority you wish to change with the arrow keys and press Enter key. The option screen opens. 2. Select the device category and press Enter key . 3. Press F4 key and save the change. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 87
You can change the priority as similar to the main boot option priorities. The 1st boot option has the highest boot priority and appears at the boot option priorities and boot order. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
You can reboot the system without saving the changes with the following instructions. 1. Select Discard Changes and Reset with the arrow keys and press Enter key. 2. Select Yes and press Enter key to discard changes and reset. Or Select No to quit. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 89
2. Select Yes and press Enter key to load optimized defaults. Or Select No to quit. Boot override All the available boot options are listed below the Boot Override. You can select any of the options to boot from a particular device. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Use a grounding wrist strap at all times. Place all electronic components on a static‐dissipative surface or in a static‐shielded bag when th ey are not in the chassis. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 91
A pair of needle nose pliers may be helpful when working with jumpers. If you have any questions about the best hardware configuration for you application, contact your local distributor or sales representative before you make any change. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 92
Appendix Motherboard A.1 Jumpers Clear COMS Note Set the jumper back to protected mode after clearing CMOS. Jumper for COM port voltage setting SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Tools & downloads Please check regularly if updates and hotfixes are available for download to your device. The download area is available on the Internet at the following link: After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
"chkdsk" is not function- EWF (Enhanced Write Filter) has Deactivate the EWF or use an alternative method to been activated. The "chkdsk" com- "chkdsk". mand is not supported if the EWF has been activated. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- Eject CD/DVD tion On/off switch, without electrical isola- tion SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
CE markings for European countries Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
DVI-D interface Line In LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Data Carrier Detect Data carrier signal detection Direct Memory Access Disk Operating System DisplayPort Deutsche Gesellschaft zur Zerti- fizierung von Qualitätsmanage- ment mBH Data Set Ready Ready for operation Data Terminal Ready Data terminal is ready SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 99
Language localization in Windows NEMA National Electrical Manufacturers Association NTFS New Technology File System NVRAM Non Volatile Random Access Non-volatile data memory. Data memory is re- Memory tained without external power supply. Optical Disk Drive SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 100
Universal Serial Bus Verband der Elektrotechnik, Elek- tronik und Informationstechnik e.V (Association for Electrical, Electronic and Information Tech- nologies) Virtualization Technology Intel technology which provides a virtual, closed environment. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 101
List of abbreviations VT-d Virtualization Technology for Enables the direct assignment of a device (e.g. Directed I/O network adapter) to a virtual device. Watchdog Program monitoring with error detection and alarming. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
EC directives such as the EMC Directive. CFast The faster SATA protocol is used with the CFast standard for memory cards based on CompactFlash. The connectors on these cards are not compatible with a classic CompactFlash card. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 103
The data are stored in a configuration file and enable the operating system to load the correct device drivers and configure the correct device parameters. . If changes are made to the hardware configuration, the user can change entries in the configuration file using the SETUP program. . SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 104
10/100/1000 Mbps. Execute Disable Capability Hardware implementation that prevents mutual memory accesses by programs and applications. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 105
Intel Active Management Technology This technology permits diagnostics, management and remote control of PCs. It is only effective when all relevant system components, such as processors, operating systems and applications are supported. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 106
Conventional drives can be used as USB devices. License key The license key represents the electronic license stamp of a license. Siemens AG issues a license key for each software that is protected by a license. License key USB flash drive The license key USB flash drive contains the authorizations or license keys required to enable protected SIMATIC software.
Page 107
Restricted Access Location: Installation of the device in a production facility with restricted access, for example, a locked control cabinet. Recovery DVD Contains the tools for configuring hard disks and the Windows operating system. Reset Hardware reset: Reset/restart of the PC using a button/switch. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 108
This design makes SSDs more rugged, provides shorter access times, low energy consumption and rapid data transfer. STEP 7 Programming software for the creation of user programs for SIMATIC S7 controllers. Troubleshooting Error cause, cause analysis, remedy SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...
Page 109
Wake on Local area network. This function allows the PC to be started via the LAN interface. Warm restart The restart of a computer after a program was aborted. The operating system is loaded and restarted again. The CTRL+ ALT+ DEL hotkey can be used to initiate a warm restart. SIMATIC IPC377E Operating Instructions, 06/2019, A5E40965249-AD...