Page 1
Preface Product description SIMATIC Safety instructions Installing and connecting the device Industrial PC SIMATIC IPC647E Commissioning the device Operating the device Operating Instructions Expanding and assigning parameters to the device Device maintenance and repair Technical specifications Dimension drawings Standards and approvals...
Page 2
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
Purpose of the operating instructions These operating instructions contain all information required to install, electrically connect and commission the SIMATIC IPC647E, to perform device expansions and to service and repair the device. They are intended for the following qualified specialist personnel: ●...
Page 4
Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats.
Note on transport and storage ....................35 Notes on mounting ........................36 Notes on ambient and environmental conditions ..............37 Information on I/O devices ...................... 39 Notes on device and system extensions ................40 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 6
Monitor hardware RAID system with "maxView Storage Manager"........76 5.4.5 Data synchronization in the RAID system ................78 Monitoring of the device ......................79 5.5.1 Monitoring functions ....................... 79 5.5.2 SIMATIC IPC DiagBase ......................81 5.5.3 SIMATIC IPC DiagMonitor ..................... 81 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 7
Replacing redundant power supply (AC) module ..............130 7.3.6 Changing the enclosure of the redundant power supply (AC) ..........131 7.3.7 Removing/installing the bus frame ..................133 7.3.8 Replacing the processor ....................... 135 7.3.9 Replacing the motherboard ....................137 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 8
DIN ISO 9001 certificate and software license agreements ..........160 10.3 UL approval .......................... 160 10.4 FCC (USA) ........................... 160 10.5 Canada ..........................162 10.6 Australia / New Zealand ....................... 162 10.7 Eurasion Customs Union EAC ..................... 162 10.8 Korea ............................ 162 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 9
Markings and symbols ........................... 191 Overview ..........................191 Safety ............................ 191 Operator controls ........................191 Certificates, approvals and markings ..................192 Interfaces ..........................193 List of abbreviations ..........................195 Abbreviations ........................195 Index ..............................197 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Supplied data storage medium • system Commissioning the operating • Online at: • system Microsoft® Windows® 10 Restoring the operating system • (https://support.industry.siemens. Configuration of the operating • com/cs/ww/en/view/109749498) system Microsoft® Windows® Server 2016 (https://support.industry.siemens. com/cs/ww/en/view/109760563) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 12
Online at: • Partition Creator Backup and restore of files, • SIMATIC IPC Image Partition • directories, drive partitions Creator (https://support.industry.siemens. com/cs/de/en/view/21766418) SIMATIC NET Industrial communication Online at: • SIMATIC NET (http://w3.siemens.com/mcms/aut omation/en/industrial- communications/Pages /Default.aspx) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Product description 1.2 Product highlights Product highlights The SIMATIC IPC647E is a high-performance industrial PC in 19" installation format (2 U). It is perfectly suited for PC applications with high-level industry functionality. Device view Note Depending on the configuration ordered the features and illustrations described in this manual may differ from the features of your device.
Page 14
– All components inside the device can only be accessed when front door is open ● Device monitoring through operating displays on the front for Ethernet; alarms for fans, temperature, Watchdog and drives in RAID1 systems SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The SIMATIC IPC has CE certification for use in the industrial sector as well as in residential and commercial areas and small businesses. In addition to the industrial applications, therefore, it can also be used in building automation or in public facilities. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Front door: lockable, protection against unauthorized access Lock • Key vertical: open • Key horizontal: closed ③ System status displays (Page 24) ④ On-off button ⑤ Mounting spaces for drives See also Interfaces (Page 20) Operator controls (Page 22) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
A (Page 101)) Components Blanking plate Removable tray (C) Removable tray lock Additional information Technical notes and information on the conditions of usage are available in the section Drives in drive cage type A (Page 101). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Mounting space for 2 x 2.5" drive internally (see Drives in drive cage internally type B (Page 110)) Components Cover Additional information Technical notes and information on the conditions of usage are available in the section Drives in drive cage type B (Page 110). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Connection for functional earthing, see "Connection of equipotential bonding line (Page 48)" ③ Interfaces (Page 20) ④ Expansion card slots on the bus board (Page 173) ⑤ Air outlet ⑥ Fixing screws for strain relief SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
2 x USB USB 3.1 GEN 2 Type C high current, backward compatible with X61/X63 USB 3.0/2.0/1.1 ⑧ 2 x 2 USB USB 3.1 GEN 2 Typ A high current, backward compatible with X60/X62/X64/X65 USB 3.0/2.0/1.1 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
① 2 × USB 3.1 Gen 1 Connectors for USB devices, backwards compatible with USB 3.0/2.0/1.1 1.4.5.2 Power supply connections Socket for power plug Sockets for power plug Simple power supply Redundant power supply SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The following figures show the location of the on/off switch on the rear of the device for devices with simple or redundant power supply. On/Off switch On/Off switch Single power supply Redundant power supply ① On/Off switch SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 23
The alarm reset button is only available for devices with redundant power supply. Use the alarm reset button to switch off the signal tone of the redundant power supply in the event of an error. ① Alarm reset button SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Possible causes: CPU temperature is critical • Device temperature is critical • ⑧ Fan status No error Possible causes: Front fan faulty • Fan of simple power supply faulty (non- • redundant power supply) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 25
B (Page 18)". The faulty drive could not be localized by the monitoring software. It may be possible to detect the defective drive with the RAID software. You can find information under "RAID1 system (Page 62)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Module is out of service, no • marking) supply module redundancy in effect. GREEN The module is in operation and • functioning. Redundancy is in effect when • both modules are operating. Module failed, no redundancy • in effect. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Power supply not connected • No drive installed • Device is switched on and a • drive is installed ② Activity Status of the drive Flashes Drive is active • Drive is not active • SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Heat sink; connected to heat transport via 2 heat pipes with heat sink of the processor ⑥ Motherboard ⑦ Retainer for expansion modules ⑧ Heat exchanger of the processor ⑨ Bus board with expansion card slots SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Accessories and spare parts 1.6.1 Hardware accessories Accessories from Siemens are available for your device that are not included in the scope of delivery. Obtaining accessories from the SIEMENS Industry Mall You can find more information in the online ordering system Industry Mall (https://mall.industry.siemens.com).
Page 30
Mini DisplayPort to DisplayPort, availa- 3 units 6ES7648-3AJ00-1XA0 ble as single-pack or 3-pack Part of the optional graphics card SIEMENS spare parts services Information on ordering, the provision and delivery of spare parts can be found under "Industry Online Support: Spare parts services (http://support.automation.siemens.com/WW/view/en/16611927)".
Access is possible even if the operating system no longer starts. Further information on the software products and references to the online catalog and ordering system (Industry Mall (https://mall.industry.siemens.com)) can be found on the SIMATIC IPC software (http://www.automation.siemens.com/mcms/pc-based- automation/en/industrial-pc/expansion_components_accessories) homepage.
Page 32
Product description 1.6 Accessories and spare parts SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
• For control cabinet mounting: Use an easily accessible central mains circuit breaker located as close to the device as possible. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 34
Electrostatic sensitive devices (ESD) The device contains electronic components that may be destroyed by electrostatic charges. This can result in malfunctions and damage to the machine or plant. Take corresponding precautionary measures before you open the device. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
• Bring the device to room temperature before starting it up. • Do not expose the device to direct heat radiation from a heating device. • If condensation develops, wait approximately 12 hours or until the device is completely dry before switching it on. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Touching these areas or components can cause death or serious bodily injury. • Always disconnect the cabinet from the mains before opening it. • Ensure that the power to the control cabinet cannot be turned on accidentally. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● Always maintain a minimum clearance of 50 mm to the area of the ventilation slots and do not cover the ventilation slots of the enclosure. ● Ensure that there is a distance of at least 50 cm at the back of the device, depending on wiring. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 38
• Avoid high-frequency radiation. • Remove radiation sources from the environment of the device. • Switch off radiating devices. • Reduce the radio output of radiating devices. • Read the information on electromagnetic compatibility. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
• The computer in question must be turned off and the power supply connector must be plugged in. • During the measurement, all cables from the plant to the computer should be connected. • All other components in the plant must be active. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● UL approval of the device only applies when the UL-approved components are used according to their "Conditions of Acceptability". ● We are not liable for functional limitations caused by the use of third-party devices or components. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
On the supplied data medium (read-only), you can find: ● Software and tools to restore your ordered Microsoft® Windows® operating system. ● Device drivers for installation in operating systems ● Quick Install Guide for SIMATIC IPC647E ● Operating instructions for SIMATIC IPC647E ● Product information ●...
Page 42
You will find the latest information on additional software for your device under: Software accessories (Page 31) Printed documents ● Quick Install Guide for SIMATIC IPC647E ● Product Information "Important notes on your device" ● SIMATIC IPC/PG Quality Control Report...
Fax the enclosed form "SIMATIC IPC/PG Quality Control Report". 5. Please keep the documentation in a safe place. It is required for initial commissioning and is part of the device. 6. Note down the Device identification data (Page 44). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The COA label is only available on devices shipped with an installed Microsoft® Windows® operating system. Example: COA label for the Microsoft® Windows® 10 operating system: See also Important instructions and manuals for operating the device (Page 11) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Horizontal: Mounting on device base This installation type meets the requirements in accordance with IEC60297-3-100. Additional information You can find more information on this in the QIG (Quick Installation Guide) that came with your device. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Detailed information on the position of the mounting holes for angle brackets or telescopic rails can be found here: Dimension drawing of the telescope rails (Page 157) and Technical specifications of the telescopic rails (Page 153). See also Hardware accessories (Page 29) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● Equipotential bonding conductor with a minimum cross section of 2.5 mm Procedure 1. Make the connection for functional ground via an equipotential bonding line to the equipotential bonding rail or grounding bar of the control cabinet in which the device is installed. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
• For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 50
Attach latch for power plug To prevent unintentional removal of the power cable, you secure the plug as follows: ① 1. Remove the retaining screw 2. Screw on the latch for the power plug ② SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
• For control cabinet mounting: Use a central, easily accessible AC circuit breaker close to the device, if possible. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 52
To prevent unintentional removal of the power cable, you secure the plug on the device as follows: ① 1. Remove the two retaining screws ② 2. Screw on the power plug latches with the ① two fixing screws SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
In the operating mode DVI video output and usage of the audio interface the user has to ensure that a ferrite (type: 742 716 33, manufacturer: Würth) is mounted with a winding at the audio cable at the exit point of the IPC. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 54
2) - via DP-VGA adapter 3) - via mDP-DP adapter 4) - via mDP to DVI-D adapter 5) - via mDP-VGA adapter You can find information on the optional graphics card under "Technical specifications of graphic (Page 151)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Control level. Additional information is available under SIMATIC NET (http://w3.siemens.com/mcms/automation/en/industrial- communications/Pages/Default.aspx). The software package and the documentation are not included in the scope of delivery Additional information You can find additional information on the Internet at: Technical support (https://support.industry.siemens.com/cs/ww/en/) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
1. Screw the strain relief onto the de- ② vice with the fastening screw 2. Insert the detachable cable ties in the respective openings of the strain relief and fasten the cables with the cable ties. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 11)". The exact minimum required downtime of the mains voltage is dependent on the device equipment and the application. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● Shut down the operating system and unplug the power plug from the rear of the device, see "Power supply connections (Page 21)". The device is switched off and fully disconnected from the mains voltage. No trickle current is flowing. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 59
– Press the power button again to turn the device back on. Hardware reset with reset button: ● Press the reset button. – The device switches off and on again. Information on the position of the buttons is available under "Operator controls (Page 22)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 60
Commissioning the device 4.3 Switching off the device SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
2. Configure the function "Multi-monitoring" in the firmware settings of the device. You can find information on this in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 11)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Storage Manager". (Page 76)". 5.4.2 RAID1 system: Installation options for drives The two hard drives required for a RAID1 system can be installed in SIMATIC IPC647E in the following locations. ● For onboard RAID system: – Drive cage type A, see "Drives in drive cage type A (Page 101)"...
6. On the next screen, assign a name for the RAID system. 7. Select "RAID Level" and select the entry "RAID1" in the following selection window. 8. Select "Select Disc". A list of the available drives is displayed. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 65
"Exit Discarding Changes" is displayed, confirm this message with "Yes". The prenumbered settings are saved nonetheless and you can leave the firmware/BIOS menu. 12. In the Main Page of the firmware/BIOS menu, select "Continue". Your device continues the boot operation and switches on. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
1. Select the "Manage" tab. Details on your onboard RAID system are displayed in the "Advanced" area. Creating a report on the onboard RAID system 1. Select the "Help" tab. 2. Select "System Report" > "Save". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Manually install a replaced drive (after a fault). You can manually install a replaced drive in the onboard RAID system as follows: ● In the running system (without restarting the device). ● After switching off the unit SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 68
4. Click on the link "Rebuild to another Disk in the "Manage" menu. 5. In the following dialog, select the newly installed drive and click on "Rebuild". The RAID system data synchronization (Page 78) is started. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The "Hardware RAID" function described below is only available as of a later stage of delivery. Contact your local SIEMENS representative. When ordering a device with hardware RAID system, all required software is already installed on your device when it is delivered.
RAID adapter card. Requirement ● 4 GB main memory ● T10 screwdriver ● Components for installing the hardware RAID adapter card. Your local SIEMENS contact person will provide you with information on these components. ① Capacitor block with capacitor block line ②...
Page 71
5.4 Operating RAID systems NOTICE Capacitor block must be discharged The original SIEMENS replacement part is supplied with a discharged capacitor block. When you remove or install a charged capacitor block, the Hardware RAID adapter card may be damaged. Data loss may result.
Page 72
6. Insert the capacitor block cable connector at the marked position. 7. Insert the adapter cable at the marked position. Make sure that the connector latch snaps in audibly. 8. Close the device. 9. Configure the installed hardware RAID adapter card. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Select entry Arrow keys on the keyboard • • Confirm selection <Return> key • • Exception: Exception: – Confirm selection when integrating drives: – <Space> keyboard Back to previous window <Esc> key • • SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 74
11. Under "Logical Drive Label", enter a name for your RAID system. 12. Select [Submit Changes] to save your settings. The message "Logical Drive Creation Successful" is displayed in the next window. 13. Select [Back to Main Menu]. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 75
<Disabled> Controller Cache <Enabled> 3. Select [Submit Changes] to save your settings. 4. Select [Back to Main Menu]. 5. Finish the process by pressing the <Return> key repeatedly. 6. Select [Exit Descarding Changes]: Yes SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
2. In the logon dialog of "maxView storage manager", enter the user name and password for your windows logon. "maxView Storage Manager" is open in Internet Explorer. In the Internet Explorer address line, the warning symbol and information on the certificate error appear. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 77
Monitor hardware RAID system with "maxView Storage Manager" You can find detailed information on the use of "maxView Storage Manager" in the user guide to the software, see "Software and documentation for the hardware RAID system (Page 69)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
In addition, system performance may be limited in the case of a manually started maintenance operation until completion of the maintenance phase. See also Change 2.5" and 3.5" drive in removable tray (Page 104) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Reset on: Hardware reset is per- • A change to the monitoring time is effective immedi- • formed ately. Reset off: No action is performed • The device is restarted. • The device is shut down. • SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 80
● SIMATIC IPC DiagBase (Page 81) for monitoring and alarming locally on the device ● SIMATIC IPC DiagMonitor (Page 81) for monitoring and alarming via network SIMATIC DiagBase or SIMATIC DiagMonitor also control the status displays of the IPC, see: System status displays (Page 24). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● Important instructions and manuals for operating the device (Page 11) Note SIMATIC IPC DiagMonitor only supports the device hardware as of version 5.1.0. Older versions do not support the device hardware. See also Software accessories (Page 31) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
(Page 11)". Software for remote maintenance of the device You can find information about the software for remote maintenance of the device and its documentation under: ● SIMATIC IPC Remote Manager (Page 83) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
You can find information on the software and documentation of SIMATIC IPC Remote Manager under: ● SIMATIC IPC Remote Manager (http://support.automation.siemens.com/WW/view/en/48707158) ● Important instructions and manuals for operating the device (Page 11) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Activating the Trusted Platform Module You can find information on activating the Trusted Platform Module in the detailed firmware/BIOS description, see "Important instructions and manuals for operating the device (Page 11)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● The front door is open; see "Opening the front door (Page 61)" (approx. 45°). ● The device is fully disconnected from the line voltage, see "Switching off the device (Page 58)". ● All connection cables are unplugged. ● T10 screwdriver SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 86
Expanding and assigning parameters to the device 6.1 Open the device Procedure 1. Open the fan cover. 2. Remove the captive screw. 3. Push the enclosure cover back. 4. Lift up and remove the enclosure cover. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Removing/installing the bus frame Requirement ● The device is open as described in the section "Open the device (Page 85)". ● Screwdriver T10 Procedure - Removal Note Observe the ESD guidelines See General safety instructions (Page 33). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 88
1. Remove the marked screws and grip the bus frame at the marked positions. 2. Careful and evenly pull the bus frame towards the top out of the device. When doing this, do not tilt the bus frame. 3. Set aside the bus frame SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 89
Expanding and assigning parameters to the device 6.2 Expansion cards 4. Unlock the marked connector and pull it out. Procedure - Installation Proceed in the opposite direction to install the bus board. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The mounting bracket may have to be removed when you replace the low expansion card with a high one. At very low cards the latching retainer can be stabilized by using a guide rail. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 91
Procedure - Removal 1. Remove the marked screws. 2. Remove the marked screws. 3. Remove the expansion cards without tilting from the slot 4. If necessary, mount a slot blank at the removal location. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 92
4. Mount the parts of the retainer according to the desired mounting position of the expansion card. Press the plastic rivets completely into the rivet body. 5. Insert the expansion card without tilting in the slot and fix it with a screw (see 2). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 93
8. If you want to change the position later, you must open the top of the bus frame. 9. Install the bus frame as described in section "Removing/installing the bus frame (Page 87)" in the device. See also Expansion card slots on the bus board (Page 173) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 95
● In faults occur, it may be enough to remove one or two memory modules or use a memory module with less capacity so that the physical memory set up on the motherboard and the reserved memory on the expansion card do not overlap. See also Open the device (Page 85) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Display of a changed memory configuration A new memory configuration is detected automatically. The allocation of the "base memory and extended memory" is automatically displayed when you switch on the device. See also Removing/installing the bus frame (Page 133) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Hold it by the upper edges only. When inserting the base, take into account the marked cutout that must match up with the coding of the base. 3. Open the two locks to the left and right of the slot. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 98
Display of a changed memory configuration A new memory configuration is detected automatically. The allocation of the "base memory and extended memory" is automatically displayed when you switch on the device. See also Removing/installing the bus frame (Page 133) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
1. Screw the guide rail of the retainer into the enclosure as shown in the figure. 2. Plug in the USB stick. 3. Slide the retainer in the direction of the USB stick. 4. Fix the retainer by turning the screw on the guide rail. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Removing the graphics card You can find information on graphics card removal under "Installing/removing expansion cards (Page 90)". Installing the graphics card You can find information on graphics card installation under "Installing/removing expansion cards (Page 90)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Drive cage type Front SATA (2.5" and 3.5" size) Enterprise (3.5" size) SAS Enterprise (3.5" size) 0 °C minimum allowable temperature for SATA hard drives 5°C minimum allowable temperature for SATA Enterprise hard drives SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Drive cage type Front SATA (2.5" and 3.5" size) Enterprise (3.5" size) SAS Enterprise (3.5" size) 0 °C minimum allowable temperature for SATA hard drives 5°C minimum allowable temperature for SATA Enterprise hard drives SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Maximum number of drives per drive type (alternative) (in removable tray) Ambient temperature 0 - 50 °C Drive cage type Front SATA (2.5" and 3.5" size) SATA Enterprise (3.5" size) SAS Enterprise (3.5" size) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● When replacing an HD: T10 screwdriver ● When replacing an SSD: T8 screwdriver Procedure 1. Open the front panel (Page 61). 2. Open the lock of the removable tray with the appropriate key. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 105
Ensure that the removable tray fits tightly in the drive cage. 10. Close the tray bracket. 11. Lock the removable tray with the key. Note The removable tray must always be locked to ensure reliable operation of the devices with removable trays. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● The device is fully disconnected from the line voltage, see "Switching off the device (Page 58)". ● The device is open, see important information in "Open the device (Page 85)". ● The drives have been removed, see "Change 2.5" and 3.5" drive in removable tray (Page 104)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 107
2. Unlock the backplane by pressing firmly in the direction of the arrow on the latching lugs ② ③ and press the ejector ④ 3. Detach the unlocked backplanes upwards from the holders and remove them from the drive cage. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 108
⑥ ● The backplane is snapped in on top behind the detent lug ● All backplanes lie precisely under one another in vertical alignment when viewed from above. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Pay attention to the following when attaching the mounting bracket: ● The groove shown is visible on the top of the drive. ● Tighten the marked screw last (tolerance compensation). Proceed in the opposite direction to install the drive. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● 10 Hz to 58 Hz: 0,0375 mm ● 58 Hz to 500 Hz: 5 m/s Vibrations may not exceed 500 Hz. Ambient temperature 0 °C - 35 °C Drive configuration Mode Non-RAID system RAID1 system SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 111
SATA Enterprise (3.5" size) 0 °C minimum allowable temperature for SATA hard drives 5°C minimum allowable temperature for SATA Enterprise hard drives See also Replacing 2.5" drives in type A drive cage (Page 109) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● 10 Hz to 58 Hz: 0,0375 mm ● 58 Hz to 500 Hz: 5 m/s Vibrations may not exceed 500 Hz. Ambient temperature 0 °C - 45 °C Drive configuration Mode Non-RAID system RAID1 system SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 113
Expanding and assigning parameters to the device 6.6 Drives Maximum number of drives per drive type (alternative) (in removable tray) Ambient temperature 0 °C - 45 °C Drive cage type Front SATA (3.5" format) SATA Enterprise (3.5" size) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
0 - 50 °C Drive configuration Mode Non-RAID system RAID1 system Maximum number of drives per drive type (alternative) (in removable tray) Ambient temperature 0 - 50 °C Drive type Front SATA (2.5" format) SATA (3.5" format) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● That you tightly screw on the side with the elongated hole (tolerance compensation). 1. Attach the mounting bar to the SSD drive. 2. Place the drives on the frame. ② 3. Connect the cables (SATA and power separated ) to the lower drive. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 116
6.6 Drives ① 4. Connect the cables (SATA and power in one plug ) to the upper drive. The cables are inserted as shown. 5. Fasten the hard drives on the frame with 4 screws. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 117
2. Press down the marked location with a suitable object (e.g. a screwdriver) until the drive faceplate is audibly released. 3. Remove the drive panel. 4. Unlock the marked connector and pull it out. 5. Press both clips inward at the same time; the drive automatically slides out. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 118
6. Pull the drive forward out of the frame. 7. Remove both drive mounting bars. Installation procedure - Drive in the frame Proceed in the opposite direction. Ensure that the mounting bars noticeably engage when the drive is inserted. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
2. Remove the marked screws and the spacer. Note The position of the spacer varies depending on the size of the M.2 NVMe SSD. The spacer for the longest M.2 NVMe SSD is installed fixed. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 120
5. Place the spacer back in, carefully push the M.2 NVMe SSD down and secure it with the screw. 6. Install the bus board again and then the bus frame; seeRemoving/installing the bus frame (Page 133). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
As soon as the Smart status of the data medium goes to "Not OK", a message is generated in SIMATIC DiagBase or SIMATIC DiagMonitor or also during a system start of the device. At this time, a data backup should be performed and the drive replaced. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The special outline of the filter ensures that it cannot be inserted contrary to the direction of flow. 3. Replace the fan cover. See also Maintenance intervals (Page 121) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
1. Open the front door at least at an angle of approx. 45°. 2. Grasp the recessed grip of the fan cover. 3. Open the fan cover in the direction of the arrow and remove it. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
③ the larger adapter plug . Repeat this step for the second fan cable plug as well. 5. Loosen the cable tie with which the two fan cables are fastened to the fan housing. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 125
10. Place the fan support with the new fan on the front of the device. See also Hardware accessories (Page 29) Maintenance intervals (Page 121) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
(Page 11)". ● The device is open, see important information in "Open the device (Page 85)". ● You have observed the local regulations relating to the disposal of used batteries. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 127
"Installing/removing expansion cards (Page 90)". 2. Remove the battery from socket. 3. Press the new battery into the socket applying slight pressure. 4. Close the device. 5. Check the firmware settings. See also Hardware accessories (Page 29) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
3. Loosen the screws marked in the following picture at the enclosure bottom. 4. Remove the screws marked in the following picture. 5. Pull the power supply upward and out of the housing. 6. Remove the mounting bracket from the enclosure of the old power supply. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 129
11. Use cable ties to reattach the power supply cables to the enclosure. 12. Close the device. 13. Check the safe state of the device. 14. Switch on the power supply. See also Hardware accessories (Page 29) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
8. Check the safe state of the device. ③ ④ 9. Switch on the new module again using the on-off switch a (status indicator of the module lights up green). See also Hardware accessories (Page 29) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
(AC) module (Page 130)". ● Short Phillips screwdriver P1 Procedure 1. Turn the screws on the marked positions with the short Phillips screwdriver. 2. Loosen the screws marked in the following picture at the enclosure bottom. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 132
14. Now, slide the enclosure all the way to the back and fix it in the appropriate locations with the screws. 15. Re-insert the two modules of the redundant power supply and close the device. See also Hardware accessories (Page 29) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
1. Remove the marked screws on the center rail of the bus frame. Note If you have not installed any expansion cards, also remove the screws from the right central support. 2. Remove the marked screws with which the piggyback is fixed to the center rail. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 134
3. Detach the piggyback from the plug-in connector and remove the piggyback upwards. 4. Remove the marked screws on the center rail of the bus frame. Procedure - Installation Proceed in the opposite direction to install the bus board. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
During positioning, make sure to take the highlighted arrow on the processor into consideration. 5. Lock the processor in place. 6. Install the heat sink of the processor again. 7. Reinstall the bus frame. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 136
Device maintenance and repair 7.3 Removing and installing hardware See also Removing/installing the bus frame (Page 133) Hardware accessories (Page 29) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
2. Note the assignment of all data cables to the motherboard and disconnect all data cables. 3. Unscrew the hexagon bolts of the COM1 port and the DVI-D port on the rear of the device, see "Interfaces (Page 20)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 138
8. Update the firmware updates accordingly to the motherboard version. Please note during the update whether you are operating a device with or without a RAID system. See also Installing/removing expansion cards (Page 90) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Note If your PC no longer boots, e.g. due to a crash during a BIOS update, contact your local SIEMENS contact person. You can find information on "BIOS Recovery" and "ME update" under "Pin assignment of the internal interfaces (Page 165)".
Contact a certified disposal service company for electronic scrap for environmentally sound recycling and disposal of your old device, and dispose of it according to the relevant regulations in your country. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The tripping characteristic of the higher- level protection must hereby take into consideration the starting currents of the IPC and those of the other devices. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 142
2500 V) Safety regulations IEC 61010-2-201 • EN 61010-2-201 • UL 61010-2-201 • CSA C22.2 No 61010-2-201 • Only with protected installation, see "Notes on ambient and environmental conditions (Page 37)" SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Depends on the selected device configuration The accumulated power of the +5 V and + 3.3 V voltage may not exceed 190 W with ATX power supply and 100 W with ATX redundant. 3 A for 10 seconds SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 144
The tripping characteristic of the higher-level protection must hereby take into consideration the starting currents of the IPC and those of the other devices. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The total sum of all voltages amounts to a max. of 230 W. The inrush current is: ● ≤ 80 A for 3.6 ms Transient voltage interruption ● 20 ms ● ≤ 10 events/h; recovery time ≥ 1 s SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The total sum of all voltages amounts to a max. of 230 W. The inrush current of a plug-in module is: ● ≤ 210 A for 1.65 ms Transient voltage interruption ● 20 ms ● ≤ 10 events/h; recovery time ≥ 1 s SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
10 V; 10 kHz up to 80 MHz • 80% AM to IEC 61000-4-6 Magnetic field 100 A/m; 50 Hz; 60 Hz (according to IEC 61000-4-8) See also Permissible expansion for temperature range 0 to 50 °C (Page 103) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Type A drive cages see "Drives in drive cage type A (Page 101)" and for Type B drive cages see "Drives in drive cage type B (Page 110)". The device must be free of any mechanical faults when HDD disk drives are installed in the removable tray. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
3.3 V / 0.4 A • Power consumption per PCIe slot 3.3 V / 3 A • with x4 expansion card, maximum 12 V / 2.1 A • permitted 3.3 V / 0.4 A • SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 150
1 x PCIe x16 (16 lanes) slot; slot 4 • 1 x PCIe x16 (4 lanes) slot; slot 1 • Expansion cards For details, see "Expansion card slots on the bus board (Page 173)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Use the original connections of the I/O to be connected without adapters or extensions. AMT and teaming cannot be used simultaneously on the Ethernet interface. See also Dimension drawing of the device (Page 155) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Partition Name Size File system First Boot 260 MB FAT32 Second 128 MB None Third System 160 GB NTFS, not compressed Fourth WinRE 500 MB NTFS, not compressed Fifth Data Remainder NTFS, not compressed SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 154
Technical specifications 8.12 Technical specifications of the operating systems SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Dimension drawings Dimension drawing of the device Note IEC 60297-3-100 The system meets the requirements for 2U according to IEC 60297-3-100. Front view and top view All dimensions in mm SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Dimension drawings 9.2 Dimension drawing of the expansion cards All dimensions in mm Dimension drawing of the expansion cards PCIe 106.7 mm 111.2 mm All dimensions in mm SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Dimensions of telescopic rails from the Rittal Type company, Type 3659 TS 3659.180 for 600 mm cabinet TS 3659.190 for 600 mm cabinet Dimensions of telescopic rails from the Heitec company RP 3659.180 for 600 mm cabinet RP 3659.190 for 600 mm cabinet SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 158
Dimension drawings 9.3 Dimension drawing of the telescope rails SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
● 2011/65/EU "Restriction of the use of certain hazardous substances in electrical and electronic equipment" (RoHS Directive) EC Declaration of Conformity The associated declaration of conformity is available on the Internet at the following address: Rack PC certificates (http://support.automation.siemens.com/WW/view/en/10805674/134200). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
DIN ISO 9001 certificate and software license agreements ISO 9001 certificate The Siemens quality management system for our entire product creation process (development, production and sales) meets the requirements of ISO 9001. This has been certified by DQS (the German society for the certification of quality management systems).
Page 161
Standards and approvals 10.4 FCC (USA) Responsible party for Supplier's Declaration of Conformity Siemens Industry, Inc. Digital Factory - Factory Automation 5300 Triangle Parkway, Suite 100 Norcross, GA 30092 mail to: amps.automation@siemens.com (mailto: amps.automation@siemens.com) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
This product meets the requirements of Korean certification. This product satisfies the requirement of the Korean Certification (KC Mark). 이 기기는 업무용(A급) 전자파 적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 가정 외의 지역에서 사용하는 것을 목적으로 합니다. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Slots for memory modules ② Processor ③ Slot for the bus board ④ Backup battery Technical features of the motherboard Technical features of the motherboard can be found under "Technical specifications of the motherboard (Page 149)". SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
LAN 2 (X2 P1) SATA 0 (Port 0) LAN 3 (X3 P1) Status indicator on front On-off button Reset button USB 3.1 USB 3.0 behind front door (X60-X65) 2x Type A 4x type A 2x type C SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
PEG interface (PCIe x16 sock- Transfer interface between motherboard and bus board. PCIe + special signal interface (PCIe x16 socket) A special USB flash drive is required for this, (not included; contact your local SIEMENS contact person). SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
NOTICE Observe safety information Only use this interface for maintenance purposes. You should observe the warnings in "Open the device (Page 85)". Name Meaning EXT_PWRBTN Input, 0 V level means Power button pressed Ground SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Data channel USB2, bidirectional Reserved + 5 V (fused) or ground USB2 (USB 2.0 contacts) -Data Data channel USB2 +Data Data channel USB2 Ground B4, 5 Open Ground B7, 8 Open + 5 V (fused) Open SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Tacho signal Input monitoring signal Output speed setting A.2.9 Supply for the serial ATA drives Name Meaning +12 V Output power supply Ground Ground +5 V Output power supply +3.3 V Output power supply SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
④ 8 x PCIe x16 (8 lanes) slot; piggy- Associated name on the rear of the device: Slot 2 back ⑤ Slot M.2 NVMe PCIe Key M x4 (4 Slot 5; internal lane) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 174
Slot PCIe x16 (16 lanes) Associated name on the rear of the device: Slot 1 ⑤ Slot M.2 NVMe PCIe Key M x4 (4 Slot 5; internal lane) See also Technical specifications (Page 141) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
PIRQ C PIRQ C PIRQ D PIRQ C INT D PIRQ C PIRQ D PIRQ D PIRQ A PIRQ D Req0 Req1 n.a. n.a. n.a. Gnt0 Gnt1 n.a. n.a. n.a. AD29 AD30 n.a. n.a. n.a. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 176
PIRQ A PIRQ A INT B PIRQ C PIRQ B PIRQ B INT C PIRQ D PIRQ C PIRQ C INT D PIRQ A PIRQ D PIRQ D See also Interrupt assignments (Page 181) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Resources may be viewed as follows under Windows: 1. Press the "Windows® key" and "R" simultaneously. 2. Enter "msinfo32" in the "Open" field. 3. Click "OK" to confirm. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The table describes the assignment of the interrupts in the delivery state of the device. Interrupt in APIC mode Host PCI-IRQ A to H is assigned to IRQ 16 to 23 permanently in APIC mode. A specific assignment cannot be forced. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
The table below shows the correlation between enclosure labeling of the IPC expansion slots and the labeling that is used during assignment of interfaces to the software in the TIA Portal. Enclosure labeling TIA Portal X100 X101 X102 X103 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 184
Hardware description A.6 Assignment of expansion interfaces to the software in the TIA Portal (CP assignment) SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
You can find additional information and support for the products described on the Internet at the following addresses: ● Technical support (https://support.industry.siemens.com/cs/ww/en/) ● Support request form (http://www.siemens.com/automation/support-request) ● After Sales Information System SIMATIC IPC/PG (http://www.siemens.com/asis) ● SIMATIC Documentation Collection (http://www.siemens.com/simatic-tech-doku-portal) ● Your local representative (http://www.automation.siemens.com/mcms/aspa- db/en/Pages/default.aspx)
If you use an adapter or extension cable for the • mouse cable make sure to check these connec- tions as well. Contact your technical support team if the mouse pointer still does not appear on the screen after these controls and measures. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 187
Activate the firmware setting "Legacy USB Sup- • the USB interfaces port" in the firmware (BIOS) under "Advanced > USB Configuration". For other devices, you need the USB device • drivers for the required operating system. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
You can find the files and descriptions needed for storage medium is aborted with damaged. this on the supplied data storage medium. the following error message: "Status: 0xc0000225 Info: The boot selection failed because a required device is inaccessible" SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
• expansion card and restart the device. If the error no longer occurs, the expansion card was the cause of the fault. Replace this with a Siemens expansion card or contact the supplier of the ex- pansion card. If the device still crashes, contact your technical support team.
Disconnect the power plug before Opening for Kensington lock opening Attention ESD (Electrostatic sensitive Warning of hot surface device) Operator controls Symbol Meaning Symbol Meaning On/off switch, without electrical isola- tion On/off switch, without electrical isola- tion SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Marking of Federal Communications Commission for the USA EFUP (Environment Friendly Use Approved for Korea Period) marking for China Test mark of the Underwriters La- Disposal information, observe the boratories local regulations. Approval for India SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
LAN interface, not approved for con- Line Out necting WAN or telephone Serial port Microphone input USB port Universal Audio Jack USB 2.0 high-speed port Headphone output USB 3.0 super-speed port USB 3.1 SuperSpeedPlus port SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Extended parallel port Extensible Firmware Interface Components sensitive to electrostatic charge European standard Hard Disk Drive Hard disk drive Height unit Input/Output Data input/output on computers iAMT Intel® Active Management Technology International Electrotechnical Commission SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 196
Universal Serial Bus V.24 ITU-T standardized recommendation for data transfer via serial ports Positive supply voltage of integrated circuits Video Graphics Array Video adapter which meets industrial standard Watchdog Program monitoring with error detection and alarming. SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Location of the interface, 20 Position of the interface on the device, 20 Condensation, 35 Expansion card, 91 Connect monitor, 54 Expansion cards Connection of equipotential bonding, 48 Slots on motherboard, 150 Connections, (Interfaces) usable expansion cards, 87 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 198
Identification data, 44, 44 Image & Partition Creator, 140 Immunity to interference, 38 Industry Mall, 29 NCQ, 149 Inrush current New Zealand, 162 Redundant power supply, 146 Single power supply, 145 Installation Expansion cards, 91 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 199
Installation options for drives, 63 Status displays Rear of the device, 19 for the system, 24 Redundant power supply Storage, 35 Inrush current, 146 Strain relief, 56 Lock for power plug, 52 Output voltage, 146 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Page 200
Uninterruptible power supply Changing the module of the redundant power supply, 130 USB 3.1 Position of the interfaces, 20, 20 Vibration-damped drive cage, 18 Voltage interruption Redundant power supply, 146 Single power supply, 145 SIMATIC IPC647E Operating Instructions, 11/2018, A5E45589180-AA...
Need help?
Do you have a question about the SIMATIC IPC647E and is the answer not in the manual?
Questions and answers