16.3 System resources
Exclusive interrupt in PIC mode
The interrupts are automatically assigned to the slots at system startup due to the default
settings in system BIOS.
Several slots may share the same interrupt, depending on the system configuration. This
functionality is known as interrupt sharing. Exclusive interrupts are not available in PIC
mode. Disable specific system resources in order to obtain exclusive interrupts. BIOS
assigns the PIC interrupts at random during restart of the system.
16.3.2.4

Memory address assignments

PCI VGA modules can be operated with expansion ROM up to 48K.
Address
from
0000 0000
0008 0000
0009 F800
000A 0000
000B 0000
000B 8000
000C 0000
000C 0000
000E 0000
0010 0000
D460 0000
F000 0000
FED0 0000
FED1 0000
FED1 8000
FED1 9000
FED1 C000
FED2 0000
FED9 0000
FEE0 0000
FF00 0000
220
Size
to
0007 FFFF
512K
0009 F7FF
127K
0009 FFFF
2K
000A FFFF
64K
000B 7FFF
32K
000B FFFF
32K
000C BFFF
48K
000C FFFF
64K
000FFFF
2 x 64K
CFFF FFFF
3.2GB
D460 0FFF
4K
F3FF FFFF
64M
FED0 03FF
1K
FED1 3FFF
16K
FED1 8FFF
4K
FED1 9FFF
4K
FED1 FFFF
16K
FED3 FFFF
128K
FED9 3FFF
16K
FEEF FFFF
1M
FFFF FFFF
16M
Description of the basic
function
Conventional system
memory
Conventional system
memory extended
XBDA, extended Bios Data
Area
VGA graphics refresh
memory
Software graphics / text
refresh memory
VGA graphics/text refresh
memory
VGA BIOS expansion
VGA BIOS
DMI data, System BIOS,
Options ROMs: PXE, RAID
System memory 4 GB
memory configuration
Motherboard resources
Motherboard resources
High Precision Event Timer
Motherboard resources
Motherboard resources
Motherboard resources
Motherboard resources
Motherboard resources
Motherboard resources
Motherboard resources
Motherboard resources
Operating Instructions, 04/2013, A5E02722710-04
Possible alternative
function
Shared SMM for
power management
Not used
Always occupied or
reserved
Depends on memory
configuration