Analog Outputs - WEG CFW100 Programming Manual

Micro mini drives
Hide thumbs Also See for CFW100:
Table of Contents

Advertisement

I/O
The indicated values are obtained after the offset action and the multiplication by the gain.
P241 - Potentiometer Signal Function
Range:
Properties:
Description:
This parameter defines the function of the potentiometer signal input.
P242 - Potentiometer Signal Gain
Range:
Description:
This parameter defines the gain of the potentiometer signal input.
P244 - Potentiometer Signal Offset
9
Range:
Description:
This parameter defines the offset of the potentiometer signal input.
P245 - Potentiometer and FI1 Filter
Range:
Description:
This parameter sets the filter time constant of the potentiometer signal (when the accessory is connected) and of
the frequency input. It attenuates sudden changes in its value.

9.4 ANALOG OUTPUTS

The analog output (AOx) is configured by means of three types of parameters: Function, Gain and Signal, according
to the block diagram in
The quantity of analog outputs depends on the expansion accessory IO's. For further details, refer to the installation,
configuration and operation guide of the IO's expansion accessory used.
9-6 | Micro Mini Drives
0 = Speed Ref.
1 to 6 = Not Used
7 = SoftPLC
8 = Application Function 1
9 = Application Function 2
10 = Application Function 3
11 = Application Function 4
12 = Application Function 5
13 = Application Function 6
14 = Application Function 7
15 = Application Function 8
16 to 17 = Not Used
cfg
0.000 to 9.999
-100.0 to 100.0 %
0.00 to 16.00 s
Figure 9.4 on page
9-7.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfw300

Table of Contents