P296 - Line Rated Voltage
Range:
0 = Reserved
1 = 110 - 127 Vac
2 = 200 - 240 Vac | 310 Vdc
3 = Reserved
4 = 380 Vac | 513 Vdc
5 = 415 Vac | 560 Vdc
6 = 440 Vac | 594 Vdc
7 = 480 Vac | 650 Vdc
Properties:
Description:
This parameter shows the inverter supply voltage according to the identification made after power up (and for
models of the 400 V Line, after adjustment).
NOTE!
200 V Line: P296 is read-only parameter (ro).
400 V Line: P296 is configuration parameter (cfg).
For further information, refer to the user's manual, available for download on: www.weg.net.
P613 - Main SW Revision
Range:
-9999 to 9999
Properties:
ro
Description:
This parameter is a counter that indicates the software revision. It is automatically generated by the machine that
compiled the firmware.

6.2 ACCESSORIES

P024 - IO Acces. SW Version
P025 - Comm. Acces. SW Version
Range:
0.00 to 99.99
Properties:
ro
Description:
They indicate the software versions of the connected microprocessors according to parameters P027 and P028.
P027 - Config. Acces. IO
P028 - Config. Comm. Acces.
Range:
0 to 10
Properties:
ro
Description:
These parameters identify the accessories that are connected according to the Quick Reference of each product.