WEG CFW100 Programming Manual page 35

Micro mini drives
Hide thumbs Also See for CFW100:
Table of Contents

Advertisement

HMI
Action
Activate password
Change password
Disable password
Disable password
(1) It only allows changing the content of the parameters when P000 is equal to the value of the password.
(2) It is allowed to change the content of the parameters and P000 is inaccessible.
P204 - Load/Save Parameters
5
Range:
Properties:
Description:
The
Table 5.2 on page 5-2
P204
0 to 4
Not Used: no action
5
Load WEG 60 Hz: it loads the default parameters on the inverter with the factory default for 60 Hz
6
Load WEG 50 Hz: it loads the default parameters on the inverter with the factory default for 50 Hz
7
Load User: it transfers the content of the memory from user parameter to the inverter current parameters
8
Not Used: no action
9
User: transfers the current content of the parameters to the user's parameter memory
10
Not Used: no action
11
Load Default SoftPLC: it loads the factory default in SoftPLC parameters (P910 to P959)
12 and 13
Reserved
In order to load the parameters of user for operating area of the inverter (P204 = 7) it is necessary that this area be
previously saved.
The operation of uploading this memory (P204 = 7), can also be done via digital inputs (DIx). For further details
referring to this programming, refer to
NOTE!
When P204 = 5 or 6, parameters P295 (Inv. Rated Current), P296 (Line Rated Voltage) and P308
(Serial Address) are not changed.
5-2 | Micro Mini Drives
Table 5.1: Required procedure for each kind of action
1. Set P200 with the desired value for the password (P200 = password)
2. The setting is completed, the new password is active and P200 is automatically adjusted for 1
(password active)
1. Set the current value of the password (P000 = password)
2. Set the desired value for the new password in P200 (P200 = new password)
3. The setting is completed, the new password is active and P200 is automatically adjusted for 1
(password active)
1. Set the current value of the password (P000 = password)
2. Set inactive password (P200 = 0)
3. The setting is completed, the password is disabled
1. Activate a factory default by means of P204
2. The setting is completed, the password is disabled
0 to 4 = Not Used
5 = Load 60Hz
6 = Load 50Hz
7 = Load User
8 = Not Used
9 = Save User
10 = Not Used
11 = Load Default SoftPLC
12 to 13 = Reserved
cfg
describes the actions performed by each option.
Table 5.2: Option of parameter P204
Section 9.6 DIGITAL INPUTS on page
Procedure
(1)
(1)
Action
(2)
(2)
9-11.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfw300

Table of Contents