P014 - AO1 Value
P015 - AO2 Value
Range:
0.0 to 100.0 %
Properties:
ro
Description:
These read-only parameters indicates the value of analog outputs AO1 and AO2 in percentage of the full scale.
The indicated values is obtained after multiplication by the gain. Check the description of the parameters P251 to
P256.
P251 - AO1 Output Function
Function
Gain
AO1 - P251
AO1 - P252
AO2 - P254
AO2 - P255
(*) Control terminals available on the accessory.
Figure 9.4: Block diagram of the analog output (AOx)
AO1 - P014
AO2 - P015
Signal
AO1 - P253
AO2 - P256
Value
(*)
AO1
(*)
AO2
Micro Mini Drives | 9-7