WEG CFW100 Programming Manual page 121

Micro mini drives
Hide thumbs Also See for CFW100:
Table of Contents

Advertisement

READ
BIT
0 to 2
3
4
5
6
7
8
9
10
11
12
13
14
15
11
11-8 | Micro Mini Drives
Table 11.4: Status word P690
Function
Reserved
-
0: Energy saving inactive
Energy Saving
1: Energy saving active
0: Output frequency reduction inactive
Fs Reduction
1: Output frequency reduction active
Reserved
-
0: No deceleration
Deceleration Ramp
1: Inverter accelerating
0: No deceleration
Acceleration Ramp
1: Inverter accelerating
0: Ramp operating in normal conditions
Frozen Ramp
1: The path of the ramp is frozen by some command source or internal function
0: Output frequency has not reached reference yet
Setpoint OK
1: Output frequency reached reference
0: DC Link Regulation inactive
DC Link Regulation
1: DC Link Regulation active
0: Factory default loaded in 60 Hz (P204 = 5)
50 Hz Config
1: Factory default loaded in 50 Hz (P204 = 6)
0: No execution of Ride-Through
Ride-Through
1: Executing Ride-Through
0: No execution of Flying Start
Flying Start
1: Executing Flying Start
0: DC breaking inactive
DC Braking
1: DC breaking active
0: PWM voltage pulses in the output disabled
PWM Pulses
1: PWM voltage pulses in the output enabled
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cfw300

Table of Contents