WEG CFW100 Programming Manual page 100

Micro mini drives
Hide thumbs Also See for CFW100:
Table of Contents

Advertisement

Output
frequency
DIx
g) LOCAL / REMOTE
If DIx is inactive, the Local command is selected, reverse the Remote command is selected.
h) JOG
The JOG command is the combination of the Run/Stop command with a speed reference via parameter P122
(Figure 9.12 on page
9-17).
Output
frequency
DIx -
Run/Stop
Active
DIx - JOG
DIx -
General Enable
i) ELECTRONIC POTENTIOMETER
The E.P. function enables the setting of the speed via digital inputs programmed for Accelerate E.P. and
Decelerate E.P.
(Figure 9.13 on page
and intensity control of electronic appliances.
The operation of the E.P. function is also affected by the behavior of parameter P120, that is, if P120 = 0 the
E.P. reference initial value will be P133; if P120 = 1 the initial value will be the last reference value before the
disabling of the inverter, and if P120 = 2, the initial value will be the reference via P121 keys.
Reverse
Active
Inactive
Figure 9.11: Example of the Direction of Rotation function
Acceleration
ramp
Active
Inactive
Inactive
Active
Figure 9.12: Example of the JOG function (E.P.)
9-18). The basic principle of this function is similar to the sound volume
Forward
Time
Time
JOG frequency
(P122)
Deceleration
ramp
Inactive
Micro Mini Drives | 9-17
I/O
Time
Time
9
Time
Time