Chapter 8 Schlage Adaptable AD-400 Series

Set PIM400 Address

The SUS is used to set the address of the PIM400. The address of the PIM should be set to the lowest number
available, from 0 to 15. A maximum of eight (8) AD-400 Locks can communicate with a PIM400 module on the
same channel, with all reader types when used with lite blue. The address used by the PIM400 and AD-400 locks
go from 0 to 15 in the SUS and 0 to 7 in the
address list of 1 through 8. When addressing a PIM400 or AD-400 lock, it is important to remember this. An
address of 0 for the PIM400 or AD-400 lock, in SUS, equals an address of 1 for the rest of the locks in
Also, The PIM400 will have the same address as the AD-400 lock with the lowest address.
When setting the address of the PIM400 you must also designate the range of addresses being used by the AD-
400 locks that will communicate with this PIM400, designating both a low and a high address for the doors. This
allows the system to know which addresses to keep open for the AD-400 locks.
Example:
A PIM400 is being added to the system, and it will have 5 AD-400 locks communicating with it. These
are the only devices on this system, so there are no other device addresses to worry about. The PIM400 will be
set at address 0, with a Low value of 0 and a High Value of 4 (meaning the AD-400 locks will be addressed from 0
lite blue
to 4). In the
through 4.
When adding multiple PIM400s to the same channel, the second PIM should have the next available address and
its LOW/HIGH range for the AD-400 locks communicating with it should start at that number.
Example:
A second PIM400 is being added to the system, on the same channel as the first above. There will be
2 AD-400 Locks communicating with this PIM400. The addresses of the original PIM400 and AD-400 locks has
already been set (see above example) so the new PIM400 will have to take this into account. The PIM400
address will be set to 5 (the next available number) and the Low value will be set to 5 and the high value will be
lite blue
set to 6. In
addressed from 5 through 6.
When adding wired locks to the same channel as a PIM400, you have to take into account the difference in
addressing.
Example:
An VBB-RI is being added to the system, as the same channel as the PIM400s above. The address of
the two PIM400s and their locks has already been set (see the above examples) so the VBB-RI will have to take
this into account. The first PIM400 and its locks are taking up addresses 0 through 4 and the second PIM400 and
its locks are taking addresses 5 through 6, so addresses 0 through 6 are taken. This counts as addresses 1
through 7 for the hardwired locks. So the VBB-RI will be put on the next available address, which is address 8.
Wired Address
1
2
3
4
5
6
7
8
VLBIM06/15/15 v4.1.0
lite blue
interface, the PIM400 will be addressed as 0 and the AD-400 locks will be addressed as 0
, this PIM400 will be addressed at 5 and the AD-400 locks communicating with it will be
Wireless Address
0
1
2
3
4
5
6
7
interface. However, the rest of the locks in
103
lite blue
use an
lite blue
.