Chapter 8 Schlage Adaptable AD-400 Series

Wiring between lite blue and PIM400 (new)

The new, smaller form factor PIM400 receives power at P2 (powered locally) and data at P4. There is a 2/4 wire
RS-485 communications jumper, P5 which must be ON (jumper installed) for 2-wire RS-485 communication on
P4. The below example is using RS485-1 on the lite blue board to P4 and P2 on the PIM400.
Data Communication and Power between lite blue and PIM400
lite blue
RS-485-1 TR+
RS-485-1 TR-
lite blue
RS-485-1 TR+
RS-485-1 TR-

PIM400 Configuration

The Schlage Utility Software (SUS) located on the included PDA must be used to configure each PIM400-485-
VBB. It is used to set the PIM400's address and the HIGH/LOW address range of the AD-400 locks that will be
communicating with it.
NOTE
: When accessing the PIM400-485-VBB with the SUS the device may be labeled as "PIM400-485-SBB"
which does not affect programming of the device and should be ignored.
VLBIM06/15/15 v4.1.0
PIM400 (legacy)
J5 RA- (jumpered at J19)
J5 RB+ (jumpered at J20)
J2 Pin 2 - PWR (Power)
J2 Pin 1 - GND (Ground)
PIM400 (new)
P4 RDA- (P5 Jumper ON)
P4 RDB+ (P5 Jumper ON)
P2 Pin 2 - PWR (Power)
P2 Pin 1 - GND (Ground)
Power Supply
+ (Power)
- (Ground)
Power Supply
+ (Power)
- (Ground)