Highlights; Standard Features; Specifications - Vanderbilt lite blue Manual

Table of Contents

Advertisement

Chapter 4 SBB-RI (Legacy)

Highlights

Supports various read head technologies; Proximity, (Wiegand Format) and Magnetic Stripe (not evaluated
by UL)
Standard 26-bit
Vanderbilt 34-bit
Xceed-ID XF1050 Reader
HID Corporate 1000 35-bit (not evaluated by UL)
HID Corporate 1000 48-bit (not evaluated by UL)
HID/ProxIF 37-Bit
XceedID 40-Bit
Vanderbilt 35-bit (including EV1)
MiFare 32-Bit Serial Number
Communicates via RS-485 protocol
Must be powered locally by an external power supply.

Standard Features

Supports one read-head credential
Connects directly to the communication channels on the lite blue controller via RS-485 protocol
Includes Two 2 amp, form C, single pole/double throw, mechanically latching relay
Connection for one multi-color LED for access granted or access denied indication
Includes 4 input contacts for devices such as exit request (REX), door position switch (DOD), etc.

Specifications

Board Dimensions - 3-13/16" x 3-13/16" x 1-3/4"D
Enclosure Dimensions - 8-1/4"H x 7-1/2W" x 3-1/2"D
Power requirements - 12 to 24 VDC (supplied by lite blue controller)
Power consumption - 300mA max. (with reader)
Ambient temperature - 0º to 49º C or 32º to 120º F
VLBIM06/15/15 v4.1.0
59